-4 Trouble locating and clearing procedures
297-8021-544 Standard 16.01 May 2003
Testing the operation of ANI and COIN voltages
(continued)
Common procedures
There are no common procedures.
Action
This procedure contains a list of steps. Follow the steps to perform the
procedure.
Testing the operation of ANI and COIN voltages using an LCM COVREX test
At the MAP
1
Access the PM level of the MAP by typing
MAPCI;MTC;PM
and pressing the Enter key.
2
Post the LCM to test by typing
POST LCM HOST <frame> <unit>
and pressing the Enter key.
where
frame
is the frame number (00 to 99)
unit
is the frame pair number (0 to 1)
3
Perform the test by typing
>TST COVREX QUERY
and pressing the Enter key.
Example response for passing test
LCM HOST 00 0 COVREX test is ON.
Recent LCM COVREX Results:
Unit0 Unit1
----- -----
PWR CRD SHORT: -7 -7 EXPECTED : -12 to 0
RING GEN : -48 -48 EXPECTED : -55 to -38
PWR CRD OPEN : 49 49 EXPECTED : 38 to 55
COIN COLLECT : 130 128 EXPECTED : 115 to 140
COIN RETURN : -129 -129 EXPECTED : -140 to -115
Last LCM COVREX test was MON. 2001/11/05 at 16:11:48;
PASSED.
Prior LCM COVREX failure was MON. 2001/11/05 at
14:19:51
1st pass following prior failure was MON. 2001/11/05
at 16:11:48
Example response for a failing test
LCM HOST 00 0 COVREX test is ON.
Recent LCM COVREX Results:
Unit0 Unit1
----- -----