When Message is Not Displayed
Trouble with Printing
Model Name: Rockhopper 62
M A P 4 0 0 0 - 2
Trouble with Printing
Model Name: Rockhopper 62
M A P 4 0 0 0 - 2
When Message is Not Displayed
When Message is Not Displayed
[Trouble with Printing]
EXA4000 to EXA4130-2
(EXA4110 to EXA4130-2
→
See MAP4001-2)
Problem
- Does not print continuously
- There is an extra feed after printing is finished
- Dots are missing from the printing
- Cleaning does not cure blockage
- Does not print at all or does not print a specific colour
- The entire surface is printed black
- Printing becomes shaded
- The image contains blurs
- Transverse lines appear to be split
- Black and white lines appear in the printed image
- Edges of printing are blurred
- Many satellites (unwanted dots)
- The printing has whiskers
- Printed lines appear blurred
- Mixed colour lines do not overlap
- Black and colour positions are offset
-
Inaccurate line length in the direction of head movement (Main scanning direction)
-
Inaccurate straight line in the direction of head movement (straightness)
Replacement and Adjustment Procedure REP. No.
Name and Diagram Number of
Replacement Part
DF-41586 Main Board Assembly
DF-40173 Vacuum Fan Assembly
DF-41620 Fan Extension Cable 1 Assembly
DF-41621 Fan Extension Cable 2 Assembly
DF-41622 Fan Extension Cable 3 Assembly
DF-41993 Fan Extension Cable 4 Assembly
DF-41605 Ink Tube
DF-41601 Head Cable
DF-41600 Y Cable
DF-41607 T Fence
DF-41602 Cap Assembly
DF-41603 Pump Assembly
DF-41599 Pump Motor Assembly
DF-40125 Wiper
DF-41604 Maintenance Station Assembly
DF-40690 Print Head Assembly (Colour)
DF-41588 Head Board Assembly
DF-41593 Detector 1 Assembly
DF-41594 Detector 2 Assembly
DF-40106 Detector Assembly (Black)
DF-40107 Detector Assembly (Y)
DF-40146 Detector Assembly (M)
DF-40147 Detector Assembly (C)
DF-41592 XR Cable Assembly (Paper Sensor R)
DF-41587 Power Board Assembly
1140
1080-2
1080-2
1080-2
1080-2
1080-2
1370
1390
1360-2
1290
1240
1260
1230
1250
1270
1390
1420
1350
1350
1350
1350
1350
1350
1200
1150
4000
4010
4020
4020
4030
4040
4050-2
4050-2
4050-2
4050-2
4060
4070
4070
4070
4080
4080
4090
4100-2
Fault-
Tracing
Procedure
EXA No.