B A C 2 1 2 0
Model Name: Rockhopper-46/62
B A C 2 1 2 0
Model Name: Rockhopper-46/62
Adjustment: Media Feed Distance
Adjustment: Media Feed Distance
This procedure is used to adjust the distance for media transport. The adjustment
determines the resolution in the firmware for the X encoder by causing lines to be
printed in the direction of media feed and entering their distance.
Adjustment Print
XLine Len:
300.0 mm
Printing finished
Print Start?
AJST: X Length
Press [ENTER] to update the settings. If settings have been changed, another adjustment print
will be made. If there was no change, the display will move to the “AJST: Margin” menu.
Displayed during adjustment printing
Setting can be specified in 0.1 mm units
using the VALUE + and - keys
When parameter is changed and [ENTER] is pressed
Press [ENTER] for another adjustment print, [Back] to
move to next menu
Media feed distance adjustment pattern
Adjustment items
Adjust the distance for media transport
Printing method
Four-pass, bidirectional 360 dpi
Standard values
Up to 500 mm
±
0.1%
Here, the adjustment is 300 mm so the actual value,
x, will be 299.7
≤
x
≥
300.3 mm
k
m c
y
300
70
150
k r g y b m c
100 %
k
k
Output direction