88
2. PROJECT CREATION
2.2 Explanation of the operating window of FR Configurator2
Graph (Z)
Screen copy
Saves the entire sub window as image data (*.bmp) to
the clipboard.
Scale optimization
Adjusts the scale of the vertical axis and the position of
zero so that the entire waveform of the selection
history can be displayed in the window.
Moving mode
Used to scroll the displayed waveform data.
Zoom-in mode
Used to zoom in the specified area of a waveform.
Cursor
Shows or hides the cursor on the screen.
Grayout
Switches the display color (color or gray scale) of the
waveform and the graph on the screen.
Overwrite
Enables or disables overwriting for all the histories.
History management...
Shows or hides the waveform history screen.
Property window
Setting
—
Shows or hides the setting tab.
Indication
—
Shows or hides the indication tab.
Cursor
—
Shows or hides the cursor tab.
Batch monitor
(Z)
Pause
Pauses the acquisition of the monitor data.
Resume
Resumes the acquisition of the monitor data.
Setting...
Sets the monitored item to be displayed.
Trend monitor...
Displays the window for selecting items to be
monitored in the form of a graph.
Trend monitor
(Z)
Pause
Pauses the acquisition of the monitor data.
Resume
Resumes the acquisition of the monitor data.
Setting...
Sets the monitored item to be displayed.
Trend monitor...
Displays a graph for each of the selected monitored
items.
All screen copy
Saves the screen displayed in all trend monitor
windows to the clipboard.
Screen copy
Saves a screen displayed in the selected trend monitor
window to the clipboard.
View
Toolbar
—
Shows or hides the trend monitor toolbar.
Status bar
—
Shows or hides the trend monitor status bar.
I/O terminal
monitor (Z)
Pause
Pause the acquisition of the I/O terminal monitor data.
Resume
Resumes the acquisition of the I/O terminal monitor
data.
Faults history
(Z)
Faults history clear
Clears the fault history of the inverter.
Inverter reset
Resets the inverter.
AI fault diagnosis
Used to find probable causes of faults using AI
technology.
Life check (Z)
Update
Refreshes the life check result.
Main circuit capacitor life measuring
Starts life measuring of the main circuit capacitor.
Online status
(Z)
All online
Sets all the devices selected in the project to online.
Connection check LED all-OFF
—
Used to turn OFF the LED on all connected inverters.
Operation mode
(Z)
PU
—
Activates the PU operation mode.
EXT
—
Activates the External operation mode.
NET
—
Activates the NET operation mode.
Menu
Pull-down menu
Toolbar
icon
Function/operation
Содержание MELSOFT FR Configurator2
Страница 7: ...6 MEMO ...
Страница 212: ...211 3 FUNCTION 3 15 Help 1 2 3 4 5 6 7 8 9 10 ...
Страница 213: ...212 3 FUNCTION 3 15 Help ...
Страница 214: ...213 CHAPTER 4 CHAPTER 4 4 5 6 7 8 9 10 TROUBLE INDICATION 4 1 Error code 214 ...