46
1. OUTLINE
1.4 Connection and parameter setting
• FR-E800-(SC)E
For details on CC-Link IE TSN communication, refer to the FR-E800 Instruction Manual (Communication).
*1
The setting is applied after an inverter reset or next power-ON.
• The parameters listed in the following table are not used for connection with the personal computer (FR Configurator2).
Set the parameters according to the application.
Pr.
Name
Initial value
Setting range
Description
541
N100
Frequency command sign
selection
0
0
Signed frequency command value
1
Unsigned frequency command value
544
N103
CC-Link extended setting
0
0, 1, 12, 14, 18,
100, 112, 114, 118
Use this parameter to extend the function of the remote
registers for the CC-Link IE TSN.
1426
N641
Link speed and duplex mode
selection
0
0 to 4
Set the communication mode (full-duplex/half-duplex).
1442
N660
IP filter address 1 (Ethernet)
0
0 to 255
Set the range of connectable IP addresses for the
network devices. (When
Pr.1442 to Pr.1445
= "0 (initial
value)", the function is invalid.)
1443
N661
IP filter address 2 (Ethernet)
0
1444
N662
IP filter address 3 (Ethernet)
0
1445
N663
IP filter address 4 (Ethernet)
0
1446
N664
IP filter address 2 range
specification (Ethernet)
9999
0 to 255, 9999
1447
N665
IP filter address 3 range
specification (Ethernet)
9999
1448
N666
IP filter address 4 range
specification (Ethernet)
9999
804
D400
Torque command source
selection
0
0, 1, 3 to 6
In the torque control mode, the torque command source
can be selected.
810
H700
Torque limit input method
selection
0
0 to 2
The torque limit input method can be selected.
Pr.
Name
Initial value
Setting range
Description
1320 to
1329
N810 to
N819
User Defined Cyclic
Communication Input 1 to 10
Mapping
9999
, 100
, 12288 to
13787, 20488,
20489, 24672,
24689, 24698,
24703, 24705,
24707, 24708,
24719, 24721,
24728 to 24730
Set the index number for inverter parameters, inverter
control parameters, and CiA402 drive profile. Functions
can be assigned to remote registers RWwn+4 to
RWwn+17 when
Pr.544
= "38".
9999
Function disabled
1330 to
1343
N850 to
N863
User Defined Cyclic
Communication Output 1 to 14
Mapping
9999
, 101
, 12288 to
13787, 16384 to
16483, 20488,
20489, 20981 to
20990, 20992
,
24639, 24643,
24644, 24673 to
24676, 24692,
24695, 24820,
24826, 24828,
25858
Set the index number for inverter parameters, monitor
data, inverter control parameters, and CiA402 drive
profile. Functions can be assigned to remote registers
RWrn+4 to RWrn+1F when
Pr.544
= "38".
9999
Function disabled
1389
User Defined Cyclic
Communication Input Sub 1
and 2 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1389
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1320Pr.1389
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1321
1390
User Defined Cyclic
Communication Input Sub 3
and 4 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1390
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1322Pr.1390
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1323