3. FUNCTION
3.1 Parameter list
• Parameter list display item
NOTE
• To display the explanation about a parameter on the help window, double-click the parameter in the parameter list.
To open the parameter file created on FR Configurator SW3 or SW1
• When the parameter file (*.pr3 or *.prm) created on FR Configurator SW3 or SW1 including both current values and setting
values is opened, "Choose parameter setting" window appears.
3.1.2
Parameter clear / all parameter clear
Performing parameter clear or all parameter clear will return the parameters to the initial values.
Symbol
Name
Function/description
A
St. No. (Station number)
Select a station registered in the project.
B
Operation mode button
Switch between the operation modes of the inverter.
C
Operation mode indication
Displays the operation mode.
D
Batch read
Reads all the parameter setting values of the selected inverter.
E
Read
Reads the selected parameter setting values of the selected inverter.
F
Batch write
Writes all the selected parameter setting values in the setting value column to the selected inverter.
G
Write
Writes all selected parameter setting values to the selected inverter.
H
All clear
Returns all parameters which can be cleared including calibration parameters and terminal function
selection parameters to their initial values.
I
Parameter clear
Returns parameters excluding calibration parameters and terminal function selection parameters to
their initial values.
J
Verify
Verifies the parameter settings set in FR Configurator2 against initial values, settings in parameter
files (*.pr4, *.pr3, *.prm), or settings in the inverter.
K
Undo
Returns the edited parameter setting value to the setting value before editing.
L
Redo
Redoes the setting value changed by "Undo" (up to 10 parameters).
M
Open
Displays the "Open" dialog box for a parameter file (*.pr4, *.pr3, and *.prm) to be opened.
N
Save as
Shows the "Save as" dialog box. Verifies the save location, and saves with the specified [File Name].
The extension for savable parameter information files is *.pr4.
The parameter list data can also be saved in the Microsoft Excel file format (*.xls) by using "File
Type" in the "Save as" dialog box.
O
Filter selection
Used to select parameters shown in the parameter list.
P
Edit Individual list
Used to set the individual list for filtering items.
Q
Display of related
parameters
Used to display items related to the parameters selected in the parameter list.
R
Settings by function
Perform settings by function: motor, terminal, trace, and position control settings.
S
Search
Searches for the input character string from within the parameter list.
T
Back
Searches for the input character string in the downward direction.
U
Next
Searches for the input character string in the upward direction.
V
Target item
Specifies the column to search.
Item
Function/description
Number
Shows the parameter number.
Calibration parameters (
Pr.902
,
903
,
904
,
905
, etc.) will be shown with ( ).
Name
Shows the parameter name.
Setting range
Shows the setting range of the parameter setting value.
Min. unit
Shows the minimum setting unit of the parameter setting value.
Initial value
Shows the factory default parameter setting values of the inverter.
Setting value
Inputs the value to be written to the inverter. The value different from the initial one is displayed in blue.
Selecting [Write] or [Batch write] will write the setting value field data to the inverter.