2. PROJECT CREATION
2.1 Project file operation
1
2
3
4
5
6
7
8
9
10
*1
When the programmable controller is protected by a remote password, automatic recognition is disabled.
• The following shows automatic recognition condition.
(
○
: Enabled, ×: Disabled)
• If the network device is protected by a remote password, the "Remote password input" dialog appears during the automatic
recognition.
2.1.3
Connection setting
In the "Connection setting" of the "System setting" window, set the communication between the personal computer and
inverter, etc.
For communication with the inverter using the USB port of personal computer, set "USB" in the box of "PC-side port".
For communication with the inverter using the serial port of personal computer, set "Specify the COM port number" in the box
of "PC-side port".
For communication with the inverter using the LAN port of personal computer, set "Ethernet" in the box of "PC-side port".
NOTE
• To use the USB/RS-485 conversion cable DINV-U4, select [COM*: DTC DINV-U4 USB Serial Port (COM*)] for the PC-side
port.
• If it is not in the drop-down list although the DINV-U4 cable is connected, do the following:
Check the DINV-U4 cable for insecure connection to the personal computer.
Check if the DINV-U4 driver is already installed in the personal computer.
FR-E700-NE
Not connected
833
Ethernet function selection 1
Set a combination of "31" (or "32") and "20" in
any two of the parameters.
834
Ethernet function selection 2
835
Ethernet function selection 3
837
to
843
Ethernet IP filter address
Set the IP address to within the IP address
range of the personal computer.
Programmable
controller
833
Ethernet function selection 1
Set "31" in any of the parameters.
834
Ethernet function selection 2
835
Ethernet function selection 3
837
to
843
Ethernet IP filter address
Set the IP address to within the IP address
range of the Ethernet module.
GOT to
programmable
controller
833
Ethernet function selection 1
Set "31" in any of the parameters.
834
Ethernet function selection 2
835
Ethernet function selection 3
837
to
843
Ethernet IP filter address
Set the IP address to within the IP address
range of the Ethernet module.
PC-side port
Intermediate device
Automatic recognition
Direct
connection
Hub connection
Router connection
Ethernet
Not connected
○
○
○
USB
GOT
×
×
×
Ethernet
GOT
○
○
○
USB
GOT to
programmable
controller
○
○
○
USB, RS-232C,
Ethernet
Programmable
controller
○
○
○
Model
Through
Pr.
Name
Setting
Содержание MELSOFT FR Configurator2
Страница 7: ...6 MEMO ...
Страница 212: ...211 3 FUNCTION 3 15 Help 1 2 3 4 5 6 7 8 9 10 ...
Страница 213: ...212 3 FUNCTION 3 15 Help ...
Страница 214: ...213 CHAPTER 4 CHAPTER 4 4 5 6 7 8 9 10 TROUBLE INDICATION 4 1 Error code 214 ...