168
3. FUNCTION
3.10 Using the Developer function
NOTE
• Developer cannot be used when a communication speed of 4800 bps or less is selected for PU connector communication
(
Pr.118
) or RS-485 terminal communication (
Pr.332
). To use Developer, set a communication speed of 9600 bps or more.
• Developer cannot be used when the 7-bit data length is selected for PU connector communication (
Pr.119
) or RS-485 terminal
communication (
Pr.333
). To use Developer, select the 8-bit data.
3.10.2 Starting the Developer function
Select [Developer] in the [Tool] menu to start Developer.
NOTE
• Use the help function of Developer to refer to the contents of the manuals relevant to Developer. Refer to the contents of the
manuals from [Help] (on
) in the Developer menu.
• To use the USB/RS-485 conversion cable DINV-U4, set RS-232C (initial setting) in the PC side I/F in the Developer
Connection Destination setting window.
• A file created by GX Developer or GX Works2 cannot be used by Developer of FR Configurator2. Conversely, a file created
by Developer of FR Configurator2 cannot be used for GX Developer or GX Works2.
Содержание MELSOFT FR Configurator2
Страница 7: ...6 MEMO ...
Страница 212: ...211 3 FUNCTION 3 15 Help 1 2 3 4 5 6 7 8 9 10 ...
Страница 213: ...212 3 FUNCTION 3 15 Help ...
Страница 214: ...213 CHAPTER 4 CHAPTER 4 4 5 6 7 8 9 10 TROUBLE INDICATION 4 1 Error code 214 ...