3. FUNCTION
3.12 Ethernet parameter setting function
1
2
3
4
5
6
7
8
9
10
4.
Select both the "Network No./station No." and "IP address/subnet mask" checkboxes.
Set the network number, station number, IP address, or subnet mask as required, and click [OK].
5.
Click [Write] to write the setting values to the inverters.
6.
Click [Yes] to reflect the settings.
7.
Select [New...] from the [Project] menu bar. In the "System setting" window, select "Ethernet" for the PC-side port
and start automatic recognition.
NOTE
• Automatic recognition is not enabled if the setting in "Inverter network No." in the "System setting" window is not consistent
with the "Network No." of the inverter in the "Ethernet parameter setting" window.
8.
Automatically-recognized inverters are displayed. Click [OK] and reflect the system setting.
9.
Click the [Online/offline] button to switch to online. The procedure is complete when the online connection is
established.