47
1. OUTLINE
1.4 Connection and parameter setting
1
2
3
4
5
6
7
8
9
10
*1
The setting is applied after an inverter reset or next power-ON.
*2
The setting is available for the FR-E800-E only.
*3
The setting is available only for the FR-E800-EPB and the FR-E800-SCEPB.
User Defined Cyclic
Communication Input Sub 5
and 6 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1391
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1324Pr.1391
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1325
User Defined Cyclic
Communication Input Sub 7
and 8 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1392
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1326Pr.1392
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1327
User Defined Cyclic
Communication Input Sub 9
and 10 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1393
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1328Pr.1393
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1329
N830?N8
39
User Defined Cyclic
Communication Input Sub 1 to
10 Mapping
0
0 to 2
Subindices to which the index numbers are specified
using
Pr.1320 to Pr.1329
User Defined Cyclic
Communication Output Sub 1
and 2 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1394
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1330Pr.1394
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1331
User Defined Cyclic
Communication Output Sub 3
and 4 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1395
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1332Pr.1395
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1333
User Defined Cyclic
Communication Output Sub 5
and 6 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1396
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1334Pr.1396
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1335
User Defined Cyclic
Communication Output Sub 7
and 8 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1397
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1336Pr.1397
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1337
User Defined Cyclic
Communication Output Sub 9
and 10 Mapping
0
0 to 2, 256 to 258,
512 to 514
Pr.1398
(lower 8 bits): Subindex to which the index
number is specified using
Pr.1338Pr.1398
(upper 8 bits):
Subindex to which the index number is specified using
Pr.1339
N870 to
N879
User Defined Cyclic
Communication Output Sub 1
to 10 Mapping
0
0 to 2
Subindices to which the index numbers are specified
using
Pr.1330 to Pr.1339
804
D400
Torque command source
selection
0
0, 1, 3 to 6
In the torque control mode, the torque command source
can be selected.
810
H700
Torque limit input method
selection
0
0 to 2
The torque limit input method can be selected.
Pr.
Name
Initial value
Setting range
Description