2. PROJECT CREATION
2.2 Explanation of the operating window of FR Configurator2
1
2
3
4
5
6
7
8
9
10
Parameter list
(Z)
PU
—
Activates the PU operation mode.
EXT
—
Activates the External operation mode.
NET
—
Activates the NET operation mode.
Batch read
Reads all the set values of the parameters of the
selected inverter.
Read
Reads the set value of the selected parameter of the
selected inverter.
Batch write
Writes all the parameter setting values entered in the
setting field to the selected inverter.
Write
Writes the set value of the selected parameter to the
selected inverter.
All clear
Returns all parameters which can be cleared including
calibration parameters and terminal function selection
parameters to their initial values.
Parameter clear
Returns parameters excluding calibration parameters
and terminal function selection parameters to their
initial values.
Verify
Verifies the parameter settings in FR Configurator2
against settings already written to the inverter.
Filter selection
—
Used to select parameters shown in the parameter list.
Edit individual list
—
Displays the window for selecting items for the
individual list used as a parameter filter.
Display of related parameters
—
Displays items related to selected parameters.
Settings
by
function
Motor
Motor setting
—
Displays the window for the motor and the control
method setting.
Offline auto tuning
—
Displays the window to perform offline auto tuning.
Acceleration/deceleration
pattern and time setting
—
Displays the window for the acceleration/deceleration
and the time setting.
Start command and
frequency setting method
—
Displays the window for the start command and
frequency setting.
Terminal
Output terminal (FM/CA)
calibration
—
Displays the window to calibrate terminal FM/CA.
Output terminal (AM)
calibration
—
Displays the window to calibrate terminal AM.
Input terminal assignment
—
Displays the window to assign functions to input
terminals.
Output terminal assignment —
Displays the window to assign functions to output
terminals.
Analog input terminal 2
calibration
—
Displays the window to calibrate terminal 2.
Analog input terminal 4
calibration
—
Displays the window to calibrate terminal 4.
Trace
Trace setting
—
Displays the window for the trace-related setting.
Trace command
—
Displays the window to perform trace commands such
as sampling start/end.
Position
control
Point table
—
Displays the window for the point table setting used for
position control.
Safety parameter
setting (Z)
Batch read
Reads all the safety parameter setting values of the
selected inverter.
Batch write
Writes all the safety parameter setting values in the
setting value column to the selected inverter.
Safety parameter clear
All safety parameters and passwords return to initial
values.
Verify
Verifies the safety parameter settings in FR
Configurator2 against settings already written to the
inverter.
Password change
Changes the registered password.
CIP Safety
Read configuration
signature
—
Displays the window to check the details of the Safety
Configuration ID (SCID) and copy the ID.
Menu
Pull-down menu
Toolbar
icon
Function/operation