4. TROUBLE INDICATION
4.1 Error code
1
2
3
4
5
6
7
8
9
10
4.1.2
Communication error with the GOT
NOTE
• If a timeout error occurs, set the FR Configurator2 to the offline mode. Check the connection of the communication cable, etc.,
and remove any error causing condition, then set it to online.
• The parameter list of FR Configurator2 shows the parameters of the latest inverter at the time of the FR Configurator2 upgrade.
(For the upgrade timing of FR Configurator2, refer to
.) The parameters' setting range, initial value, and numbers may
be different before and after a version upgrade (with functions added).
• Refer to
for information on communication errors with the GOT (error codes: 0x01808301 and 0x0180840B).
0x90010101
Communication was not
established with the inverter
within the timeout time.
PROFINET is selected in any of
Pr.1427 to Pr.1430 Ethernet
function selection
.
Do not set "34962" in any of
Pr.1427
to Pr.1430 Ethernet function
selection
.
0x90A00101
The communication line cannot
be opened.
The IP address is used by another
inverter.
Set a unique IP address.
0x90F00001
The communication settings
cannot be written.
The inverter series name is
unknown.
• Upgrade FR Configurator2 to the
latest version.
• Write the communication settings
from the operation panel. For
information on the communication
settings, refer to the Instruction
Manual of the inverter.
0x90F00002
The inverter model is unknown.
Error code (HEX)
Error message
Possible cause
Countermeasure
Error code (HEX)
Error message
Possible cause
Solution
0x80110001
An unexpected error occurred in
S/W.
GOT type error.
Check for the GOT type.
0x80110002
0x80110003
An unexpected error occurred in
S/W.
Please contact your sales representative.
0x80110004
Communication was not
established with the inverter
within the timeout time.
• Communication protocol of the
inverter and the GOT are not the
same.
• Setting of
Pr.122 PU
communication check time
interval
,
Pr.336 RS-485
communication check time
interval
,
Pr.548 USB
communication check time
interval
is other than "0".
• Electromagnetic interference
• Cable breakage/damage
• Set the same communication
protocol for the inverter and the
GOT.
• Set a value other than "0" in
Pr.122
PU communication check time
interval
,
Pr.336 RS-485
communication check time
interval
,
Pr.548 USB
communication check time
interval
.
• Set a larger value for the timeout
setting of the software.
• Cable connection/replacement.
Check for communication cable and
power supply of devices.
0x80110005
Communication was not
established with the inverter
within the timeout time.
GX drawing software was started
when FR Configurator2 was
starting.
After closing GX drawing software, try
communication again.
0x80110006
Communication was not
established with the inverter
within the timeout time.
GX drawing software was started
when FR Configurator2 was
starting.
After closing GX drawing software, try
communication again.
0x80110007
An unexpected error occurred in
S/W.
Communication line quality error
Set lower baud rate and make a
communication.
0x80110008
An unexpected error occurred in
S/W.
Baud rate not supported by
connected device
Check for the baud rate supported by
connected devices.
0x80110009
Communication was not
established with the inverter
within the timeout time.
• Electromagnetic interference
• Cable breakage/damage
• Set a larger value for the timeout
setting of the software.
• Cable connection/replacement.
Check for the connection.
0x8011000A
Communication was not
established with the inverter
within the timeout time.
Other process is ongoing in the
GOT and line is BUSY.
(retry is performed in the
EZSocket)
A station not connected is being
monitored.
• Set a larger value for the timeout
setting of the software.
• Monitor only the station which the
GOT is connected.
• Check that the GOT is operating
correctly and try again.