3. FUNCTION
3.3 Convert
1
2
3
4
5
6
7
8
9
10
To convert from FR-B3 (A700) inverters to FR-B3 (A800) inverters
• Set the following parameters as required in the "Parameter list" window because they are not converted.
Pr.69 Retry count display erase
Pr.170 Watt-hour meter clear
Pr.171 Operation hour meter clear
Pr.172 to Pr.174 (User group selection)
Pr.259 Main circuit capacitor life measuring
Pr.498 PLC function flash memory clear
Pr.501 (Communication option parameter)
Pr.503
,
Pr.686
, and
Pr.688 (Maintenance timer)
Pr.610 PID measured value input selection
Pr.805 Torque command value (RAM)
Pr.898 Power saving cumulative monitor clear
Pr.991 PU contrast adjustment
Pr.1006 to Pr.1008 (Clock function)
Pr.1020 Trace operation selection
• It is recommended to adjust the setting of the following parameters again after conversion according to the mechanical
system because they are used for adjustment.
Pr.12 DC injection brake operation voltage
C2 (Pr.902) to C7 (Pr.905)
(Frequency setting input calibration parameters)
• Since the communication-related parameters (
Pr.117 to Pr.124, Pr.331 to Pr.337, Pr.341, Pr.547,
and
Pr.548
) are also
converted, communication may be disabled depending on the setting after the setting is written to parameters. For
example, when
Pr.122
/
Pr.336 RS-485 communication check time interval
= "0 (initial value)", a communication error
(E.PUE, E.SER) occurs immediately after the operation mode with the command source is selected.
• If "63" is set in
Pr.184 AU terminal function selection
to enable the PTC thermal error detection (E.PTC) in the source
FR-B3 (A700) inverter, setting of
Pr.561
and
Pr.1016
and connecting the motor to the target FR-B3 (A800) inverter via
terminals 2 and 10 are required. For the parameter details and terminal connection, refer to the Instruction Manual of the
inverter.
To convert from FR-A500(L) inverters to FR-A800(-E) inverters
• Set the following parameters as required in the "Parameter list" window because they are not converted.
Pr.69 Retry count display erase
Pr.96 Auto tuning setting/status
Pr.133 PID action set point
Pr.170 Watt-hour meter clear
Pr.171 Operation hour meter clear
Pr.172 to Pr.174 (User group selection)
Pr.259 Main circuit capacitor life measuring
Pr.463 Second motor auto tuning setting/status
Pr.496 Remote output data 1
Pr.497 Remote output data 2
Pr.498 PLC function flash memory clear
Pr.501 (Communication option parameter)
Pr.503
,
Pr.686
, and
Pr.688 (Maintenance timer)
Pr.805 Torque command value (RAM)
Pr.898 Power saving cumulative monitor clear
Pr.991 PU contrast adjustment
Pr.1006 to Pr.1008 (Clock function)
Pr.1020 Trace operation selection