1. OUTLINE
1.4 Connection and parameter setting
1
2
3
4
5
6
7
8
9
10
*2
Parameters which can be displayed when this plug-in option (FR-A8NCG) is installed.
*3
The initial value after All parameter clear with the FR-A8NCG installed.
IP address setting
• For CC-Link IE TSN communication, the IP address of the inverter is set using the station number switches on the
communication circuit board of the FR-A8NCG or inverter parameters. Note that the station number switch
setting has a
higher priority than the parameter setting. (When the station number switches are not set to "0 or 255", the station number
switch setting has a higher priority than the
Pr.437
setting.) For CC-Link IE TSN communication, the third octet of the
inverter's IP address is used as the network No. and the fourth octet is used as the station number. (Enter the IP address
assigned by the network administrator.)
*1
For details on the station number switches, refer to the CC-Link IE TSN Function Manual or FR-A8NCG Instruction Manual.
Setting the IP address with the station number switches
• Set a value other than "0 (H00)" or "255 (HFF)" to specify a station number using the station number switches. The setting
range is from "1 (H01)" to "254 (HFE)". The setting is applied after an inverter reset or at the next power-ON.
Setting the IP address with parameters (Pr.434 to Pr.437)
• Set the station number switches to "0 (H00)" or "255 (HFF)" to specify the IP address of the inverter using
Pr.434 to Pr.437
.
The setting is applied after an inverter reset or at the next power-ON.
• Enter the inverter network number in
Pr.436 IP Address 3
.
• The setting range of
Pr.436
is "0 to 255", but its active range is "1 to 254". The values out of the active range are invalid
because such values cannot be transmitted to the master station.
• Specify the inverter station number in
Pr.437 IP Address 4
.
• The setting range of
Pr.437
is "0 to 255", but its active range is "1 to 254". Out-of-range setting values are invalid because
such values cannot be transmitted to the master station.
Related parameters for connection using CC-Link IE TSN (for FR-E800-
(SC)E inverter)
• For details on CC-Link IE TSN communication, refer to the FR-E800 Instruction Manual (Communication).
IP address
Description
First octet
The settings of the master station are used. (The settings from
Pr.434 to Pr.436
are invalid.)
Second octet
Third octet
Fourth octet
The station number switch setting is enabled regardless of the setting in
Pr.437
.
IP address
Description
First octet
Pr.434
Second octet
Pr.435
Third octet
Pr.436
Fourth octet
Pr.437
Pr.
Name
Initial value
Setting range
Description
541
N100
Frequency command sign
selection
0
0
Signed frequency command value
1
Unsigned frequency command value
544
N103
CC-Link extended setting
0
0, 1, 12, 14, 18, 38,
100, 112, 114, 118,
138
Use this parameter to extend the function of the remote
registers for the CC-Link IE TSN.
1424
N650
Ethernet communication
network number
1
1 to 239
Enter the network number.
1425
N651
Ethernet communication
station number
1
1 to 120
Enter the station number.
1426
N641
Link speed and duplex mode
selection
0
0 to 4
Set the communication mode (full-duplex/half-duplex).