3.12 Ethernet parameter setting function
1
2
3
4
5
6
7
8
9
10
At the initial startup, inverters are detected automatically.
NOTE
• For using the Ethernet parameter setting, connect the inverter and the personal computer directly via Ethernet or using a hub.
• The inverter and the personal computer must have the same IP address. If they have different IP addresses, the network
number and the station number cannot be set.
• The LED all-OFF setting and the connection check ON/OFF setting are available for FR-E800-E inverters connected directly
by Ethernet.
• Those settings are enabled when online communication is established between the inverter and FR Configurator2.
• LEDs may not blink depending on the
Pr.1399
setting even when the connection check is enabled. Refer to the Instruction
Manual of the inverter for the details.
• When FR-E800-E inverters are connected in line topology, writing to two or more inverters at the same time may cause a
communication error.
A
L
B
N
J
I
H
G
F
E
D
C
M
P
Q
K
O
Symbol
Name
Function/description
A
Inverter detection
Detects the inverter(s) connected via Ethernet to read and indicate the parameters.
B
Target inverter checkbox
Select the target inverter(s) to perform [Batch assign] or [Write].
C
Model
Shows the model of the connected inverter.
D
Capacity
Shows the capacity of the connected inverter.
E
Network No.
Set the inverter network number. (For FR-A800-E, FR-F800-E, and FR-E800-(SC)E, refer to
Pr.1424
. For FR-A800-E-R2R, refer to
Pr.1073
. For FR-E700-NE, refer to
Pr.830
.)
F
St. No.
Set the inverter station number to be written to the inverter. (For FR-A800-E, FR-F800-E, and FR-
E800-(SC)E, refer to
Pr.1425
. For FR-A800-E-R2R, refer to
Pr.1074
. For FR-E700-NE, refer to
Pr.831
.)
G
MAC address
Shows the MAC address of the connected inverter.
H
Host Name
Set the host name to be written to the inverter. Up to 16 characters can be entered. Single-byte
letters and numbers, hyphens (-), periods (.), colons (:), and underscores (_) can be entered.
I
IP address
Enter the IP address to be written to the inverter.
J
Subnet mask
Enter the Subnet mask to be written to the inverter.
K
Connection check
ON
Used to turn ON the NET LEDs on successfully connected inverters to blink in the communication
check of FR Configurator2. (The blinking of LEDs will automatically stop five minutes after the start
of blinking.)
OFF
Used to stop the blinking of the NET LEDs on successfully connected inverters in the
communication check of FR Configurator2.
L
Select all
Selects all inverters in the list.
M
Unselect all
Clears selection of all inverters in the list.
N
Select inverter with no
setting
Selects inverters for which the series name is indicated in the model field.
O
Connection check LED all-
OFF
Used to stop the blinking of the NET LEDs on all successfully connected inverters.
P
Batch assign...
Shows the batch assignment dialog.
Q
Write
Writes the network number, station number, host name, IP address, and subnet mask to the
inverters with a check in the checkbox.