4.1.4
Changing the parameter setting value
Changing
example
Change the
Pr. 1 Maximum frequency
setting.
Operation Display
1.
Screen at power-ON
The monitor display appears.
2.
Changing the operation mode
Press
to choose the PU operation mode.
PU indicator is lit.
3.
Parameter setting mode
Press
to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously
appears.)
4.
Selecting the parameter number
Turn
until
(Pr. 1)
appears.
5.
Displaying the setting
Press
to read the present set value.
"
"(120.0Hz (initial value)) appears.
6.
Changing the setting value
Turn
to change the set value to
"
" (60.00Hz).
7.
Parameter setting
Press
to set.
Flicker...Parameter setting complete!!
Turn
to read another parameter.
Press
to show the setting again.
Press
twice to show the next parameter.
Press
twice to return to frequency monitor.
REMARKS
is displayed...Why?
appears .................... Write disable error
appears .................... Write error during operation
appears .................... Calibration error
appears .................... Mode designation error
(For details,
refer to page 298
.)
The number of digits displayed on the operation panel is four. Only the upper four digits of values can be displayed and set. If the
values to be displayed have five digits or more including decimal places, the fifth or later numerals cannot be displayed nor set.
(Example) For
Pr. 1
When 60Hz is set, 60.00 is displayed.
When 120Hz is set, 120.0 is displayed and second decimal place is not displayed nor set.