![Mitsubishi Electric FR-F700PJ Series Скачать руководство пользователя страница 232](http://html.mh-extra.com/html/mitsubishi-electric/fr-f700pj-series/fr-f700pj-series_instruction-manual_239805232.webp)
227
Communication operation and setting
(3) Communication operation presence/absence and data format types
Data communication between the computer and inverter is made in ASCII code (hexadecimal code).
Communication operation presence/absence and data format types are as follows:
Data writing format
Communication request data from the computer to the inverter 1)
Reply data from the inverter to the computer 3) (No data error detected)
Reply data from the inverter to the computer 3) (With data error)
No.
Operation
Run
Command
Operation
Frequency
Multi
command
Parameter
Write
Inverter
Reset
Monitor
Parameter
Read
1)
Communication request is sent to the
inverter in accordance with the user
program in the computer.
A1
A, A2
A3
A, A2
A
B
B
2)
Inverter data processing time
Present
Present
Present
Present
Present
Present
Present
3)
Reply data from the
inverter (Data 1) is
checked for error)
No error
(Request
accepted)
C
C
C1
C
C
E, E1, E2,
E3
E, E2
With error
(Request
rejected)
D
D
D
D
D
D
D
4)
Computer processing delay time
10ms or more
5)
Answer from
computer in response
to reply data 3).
(Data 3) is checked
for error)
No error
(No inverter
processing)
Absent
Absent
Absent
(C)
Absent
Absent
Absent
(C)
Absent (C)
With error
(Inverter outputs
3) again.)
Absent
Absent
F
Absent
Absent
F
F
In the communication request data from the computer to the inverter, 10ms or more is also required after "no data error (ACK)". (
Reply from the inverter to the inverter reset request can be selected
.
When any of "0.01 to 9998" is set in
Pr. 37
and "01" in instruction code, HFF sets data format to A2 or E2. In addition, data format is always A2 and E2
for read or write of
Pr. 37
.
At mode error, and data range error, C1 data contains an error code.
Except for those errors, the error is returned with data format
D.
Format
Number of Characters
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
A
ENQ
Inverter
station
number
Instruction
code
Data
Sum
check
A1
ENQ
Inverter
station
number
Instruction
code
Data
Sum
check
A2
ENQ
Inverter
station
number
Instruction
code
Data
Sum
check
A3
ENQ
Inverter
station
number
Instruction
code
Send
data
type
Receive
data
type
Data1
Data2
Sum
check
Format
Number of Characters
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
C
ACK
Inverter
station
number
C1
STX
Inverter
station
number
Send
data
type
Receive
data
type
Error
code 1
Error
code 2
Data1
Data2
ETX
Sum
check
Format
Number of Characters
1
2
3
4
5
D
NAK
Inverter
station
number
Error
code
Indicate a control code
Specify the inverter station numbers between H00 and H1F (stations 0 to 31) in hexadecimal.
Set waiting time. When the
Pr. 123 PU communication waiting time setting
is other than "9999", create the communication request data without "waiting time"
in the data format. (The number of characters decreases by 1.)
CR, LF code
When data is transmitted from the computer to the inverter, codes CR (carriage return) and LF (line feed) are automatically set at the end of a data group
on some computers. In this case, setting must also be made on the inverter according to the computer. Whether the CR and LF codes will be present or
absent can be selected using
Pr. 124 PU communication CR/LF selection
.
Содержание FR-F700PJ Series
Страница 13: ...IX MEMO ...
Страница 29: ...16 MEMO ...
Страница 76: ...63 MEMO ...
Страница 299: ...294 MEMO ...
Страница 321: ...316 MEMO ...
Страница 346: ...341 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...