99
Adjustment of the output torque (current) of the motor
(7) To further prevent a trip
(Pr.154)
Set
Pr.154
= "11" when the overvoltage protective function (E.OV
) activates during stall prevention operation in an
application with large load inertia. Note that turning OFF the start signal (STF/STR) or varying the frequency signal during
stall prevention operation may delay the acceleration/deceleration start.
(8) Limit the stall prevention operation and fast-response current limit operation according to the
operating status
(Pr. 156)
Refer to the following table and select whether stall prevention operation and fast-response current limit operation will be
performed or not and the operation to be performed at OL signal output.
When "Operation not continued for OL signal output" is selected, the
fault (stopped by stall prevention) is displayed and operation is stopped.
Since stall prevention is not activated, OL signal and E.OLT are not output.
The settings "100" and "101" allow operations to be performed in the driving and regeneration modes, respectively. The setting "101" disables the fast-
response current limit in the driving mode.
OL signal is not output at fast-response current limit operation.
The fast-response current limit operation is disabled under IPM motor control.
Pr. 156
Setting
Fast-Response
Current Limit
: Activated
: Not activated
Stall Prevention
Operation Selection
: Activated
: Not activated
OL Signal
Output
:Operation
continued
: Operation
not continued
Pr. 156
Setting
Fast-Response
Current Limit
: Activated
: Not activated
Stall Prevention
Operation Selection
: Activated
: Not activated
OL Signal
Output
:Operation
continued
: Operation
not continued
Ac
ce
le
ra
tio
n
C
ons
ta
nt
sp
ee
d
De
ce
le
ra
tio
n
Ac
ce
le
ra
tio
n
C
ons
ta
nt
sp
ee
d
De
ce
le
ra
tio
n
0
(initial
value)
16
1
17
2
18
3
19
4
20
5
21
6
22
7
23
8
24
9
25
10
26
11
27
12
28
13
29
14
—
30
—
15
—
31
—
100
P
o
w
e
r d
riv
in
g
101
P
o
w
e
r d
riv
in
g
Regenerat
ion
—
Regenerat
ion
—
NOTE
When the load is heavy or the acceleration/deceleration time is short, stall prevention is activated and acceleration/
deceleration may not be made according to the preset acceleration/deceleration time. Set
Pr. 156
and stall prevention
operation level to the optimum values.
In vertical lift applications, make setting so that the fast-response current limit is not activated. Torque may not be
produced, causing a load drop due to gravity.