157
Monitor display and monitor output signal
4.12.3 Reference of the terminal FM (pulse train output) (Pr. 55, Pr. 56)
The pulse train output terminal FM is available for monitor output.
Set the reference of the signal output from terminal FM.
Parameter
Number
Name
Initial Value
Setting Range
Description
55
Frequency monitoring
reference
60Hz
0 to 400Hz
Full-scale value when frequency monitor value is
output to terminal FM.
56
Current monitoring
reference
Rated inverter
current
0 to 500A
Full-scale value when current monitor value is
output to terminal FM.
The above parameters can be set when
Pr. 160 Extended function display selection
=
"
0
"
.
The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set in
Pr. 77 Parameter write
selection
.
Performing IPM parameter initialization changes the settings.
(1) Frequency monitor reference
(Pr. 55)
Set the full scale value when outputting the frequency monitor from terminal FM.
Set the frequency when the optional frequency meter (1mA analog meter), which is connected to the terminal FM and
SD, shows 60Hz or 120Hz (shows full scale).
Set the inverter output frequency (set frequency) at which the pulse speed of the FM output is 1440 pulses/s.
The pulse speed and inverter output frequency are proportional to each other. (The maximum pulse train output is 2400
pulses/s.)
(2) Current monitor reference
(Pr. 56)
Set the full scale value when outputting the current monitor from terminal FM.
Set the output current at which the pulse speed of the FM output is 1440 pulses/s.
The pulse speed and output current monitor value are proportional to each other. (The maximum pulse train output is
2400 pulses/s.)
1Hz
60Hz
(initial value)
Output frequency 400Hz
Setting range of
Pr. 55
Pulse speed
(pulses/s)
2400
1440
Rated current
(initial value)
500A
Setting range of
Pr. 56
Pulse speed
(pulses/s)
2400
1440