LSI Corporation
- 83 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 4: Ctrl-R Utility
Viewing and Changing Device Properties
—
Stop Erase
: Stops the erase operation that has already been started. This option is disabled at first. Once the
erase operation begins, this option is enabled.
3.
Select a mode and press Enter.
A message box appears.
Figure 54 Erase Virtual Drive
4.
To delete the virtual drive after the erase operation has been completed, select the
Delete Virtual Drive after
Erase operation
check box.
5.
Press
Yes
for the erase operation to start.
Once the Drive Erase operation has started, the
Simple
,
Normal
, and
Thorough
options are disabled and the
Stop Erase
option is enabled.
4.13.8
Managing Link Speed
The Managing Link Speed feature lets you change the link speed between the controller and an expander, or between
the controller and a drive that is directly connected to the controller.
All phys in a SAS port can have different link speeds or can have the same link speed.
You can select a link speed setting. However, if phys in a SAS port have different link speed settings and if a phy is
connected to a drive or an expander, the firmware overrides the link speed setting you have selected. Instead, the
firmware uses the common maximum link speed among all the phys.
Perform the following steps to change the link speed:
1.
In the
Controller Settings
screen, press
Next
.
The second
Controller Settings
screen appears.
2.
Press
Manage Link Speed
.
The
Manage Link Speed
dialog appears.