LSI Corporation
- 91 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 4: Ctrl-R Utility
Managing Storage Configurations
CAUTION
Make sure to back up the data before you run a consistency check, if
you think the data might be corrupted.
Perform the following steps to run a consistency check:
1.
Navigate to a virtual drive in the
VD Mgmt
screen, and press the F2 key.
2.
Navigate to
Consistency Check
, and press Enter.
3.
Navigate to
Start
, and press Enter.
The consistency check starts and checks the redundant data in the virtual drive.
If you attempt to run a consistency check on a virtual drive that has not been initialized, a confirmation dialog
appears, asking for your confirmation.
Figure 63 Consistency Check
4.
Press
Yes
to run the consistency check.
4.14.3
Rebuilding a Physical Drive
If a drive in a redundant virtual drive (RAID 1, 5, 6, 10, 50, or 60) fails, you must rebuild that drive on a hot spare drive to
prevent data loss.
Perform the following steps to rebuild a physical drive:
1.
Navigate to the
Drive Management
screen (in the
PD Mgmt
menu), and press the F2 key.
2.
Select
Rebuild
, and press Enter.
The rebuild operation starts.
4.14.4
Performing a Copyback Operation
You can perform a copyback operation on a selected drive.
The copyback operation copies data from a source drive of a virtual drive to a destination drive that is not a part of the
virtual drive. The copyback operation often creates or restores a specific physical configuration for a drive group (for
example, a specific arrangement of drive group members on the device I/O buses).
Perform the following steps to perform the copyback operation:
1.
Navigate to the
Drive Management
screen, navigate to a physical drive, and press the F2 key.
2.
Navigate to
Copyback
, and press Enter.
Содержание ThinkServer RD650
Страница 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Страница 417: ......
Страница 418: ......