Chapter 9: Configuration
Converting JBOD Drives to Unconfigured Good
9.2
Converting JBOD Drives to Unconfigured Good
You can convert JBOD drives to Unconfigured Good using the
Create Virtual Drive
option or
Make Unconfigured
Good
drive option with a single configuration.
NOTE
MegaRAID SAS 9240-4i and MegaRAID SAS 9240-8i controllers
support JBOD.
Perform the following steps to configure JBOD to Unconfigured Good drives:
1.
Perform one of these actions:
—
Right-click the controller node in the device tree in the left frame of the
MegaRAID Storage Manager
window, and select
Create Virtual Drive
.
—
Select the controller node, and select
Go To > Controller > Create Virtual Drive
.
The
Create Virtual Drive - JBOD to Unconfigured Good Conversion
wizard appears, as shown in the following
figure.
Figure 163 Create Virtual Drive - JBOD to Unconfigured Good Conversion Dialog
The
JBOD Drives
field displays the available JBOD drives available in the system.
2.
Select the drives which you want configured as Unconfigured Good and then click
Convert
. Clicking on
Convert
configures the selected JBODs to Unconfigured Good Drives.
NOTE
If you do not want to make any JBOD as unconfigured good drives,
select the
Do not convert JBOD drives to unconfigured good drives
check box, and the MegaRAID Storage Manager application skips
changing any selected JBOD to unconfigured good drive.