LSI Corporation
- 129 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 5: The HII Configuration Utility
Managing Controllers
Figure 93 Controller Firmware Update
Follow these steps to upgrade the firmware:
1.
To specify the file system where the
.rom
update file resides, highlight
Select File System
and press Enter. Select
the file system and press Enter.
2.
To specify the directory where the
.rom
file resides, highlight
Select Directory
and press Enter. Browse to the
required the directory and press Enter.
The current directory is normally highlighted. You may browse to only one level higher or one level lower.
3.
To specify the
.rom
file, highlight
Select Image
and press Enter. Select the
.rom
file and press Enter.
4.
Highlight
Update
and press Enter.
The following Warning dialog appears.
Figure 94 Firmware Update Warning
5.
Highlight the
Confirm
check box and press the spacebar to select the check box.