12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x018d
Warning
Cache-vault microcode update
required
Logged when the BMU is not in Normal mode and
Cache-vault microcode update required.
0x018e
Warning
CacheCade (%s) capacity exceeds
maximum allowed size, extra
capacity is not used
Logged when CacheCade capacity exceeds maximum
allowed size, extra capacity is not used.
0x018f
Warning
LD (%s) protection information lost
Logged when the protection information is lost for an LD.
0x0190
Information
Diagnostics passed for %s
Logged when the SHIELD Diagnostics passed for a PD.
0x0191
Critical
Diagnostics failed for %s
Logged when the SHIELD Diagnostics failed for a PD.
0x0192
Information
Server Power capability Diagnostic
Test Started
Logged when the Server Power capability Diagnostic Test
starts.
0x0193
Information
Drive Cache settings enabled during
rebuild for %s
Logged when the Drive Cache settings enabled during
rebuild for a PD.
0x0194
Information
Drive Cache settings restored after
rebuild for %s
Logged when the Drive Cache settings restored after rebuild
for a PD.
0x0195
Information
Drive %s commissioned as
Emergency spare
Logged when the Drive commissioned as Emergency spare.
0x0196
Warning
Reminder: Potential non-optimal
configuration due to drive %s
commissioned as emergency spare
Logged when the PD being imported is an Emergency Spare.
0x0197
Information
Consistency Check suspended on %s Logged when the Consistency Check is suspended on an LD.
0x0198
Information
Consistency Check resumed on %s
Logged when the Consistency Check is resumed on an LD.
0x0199
Information
Background Initialization suspended
on %s
Logged when the Background Initialization is suspended on
an LD.
0x019a
Information
Background Initialization resumed
on %
Logged when the Background Initialization is resumed on an
LD.
0x019b
Information
Reconstruction suspended on %s
Logged when the Reconstruction is suspended on an LD.
0x019c
Information
Rebuild suspended on %
Logged when the Rebuild is suspended on a PD.
0x019d
Information
Replace Drive suspended on %s
Logged when the Replace is suspended on a PD.
0x019e
Information
Reminder: Consistency Check
suspended on %
Logged as a reminder when the Consistency Check is
suspended on an LD.
0x019f
Information
Reminder: Background Initialization
suspended on %s
Logged as a reminder when the Background Initialization is
suspended on an LD.
0x01a0
Information
Reminder: Reconstruction
suspended on %s
Logged as a reminder when the Reconstruction is suspended
on an LD.
0x01a1
Information
Reminder: Rebuild suspended on %s Logged as a reminder when the Rebuild is suspended on a
PD.
0x01a2
Information
Reminder: Replace Drive suspended
on %s
Logged as a reminder when Replace is suspended on a PD.
0x01a3
Information
Reminder: Patrol Read suspended
Logged as a reminder when the Patrol Read is suspended.
0x01a4
Information
Erase aborted on %s
Logged when the Erase is aborted on a PD.
0x01a5
Critical
Erase failed on %s (Error %02x)
Logged when the Erase is failed on a PD along with the error.
0x01a6
Progress
Erase progress on %s is %s
Logged to display the Erase progress on a PD along with its
current progress.
0x01a7
Information
Erase started on %s
Logged when Erase is started on a PD.
0x01a8
Information
Erase completed on %s
Logged when the Erase is completed on a PD.
0x01a9
Information
Erase aborted on %s
Logged when the Erase is aborted on an LD.
Number
Severity
Level
Event Text
Generic Conditions when Each Event Occurs