6.6.9
BBU Commands
The Storage Command Line Tool supports the following battery backup unit (BBU) commands:
NOTE
To increase the life of a battery, the battery is not fully charged. Band
Gap charging keeps the maximum battery charge within a band
comfortably above the data retention time requirement instead of
keeping the battery charged to the maximum level. However, when a
learn cycle is required, the battery is fully charged because a learn
cycle starts only once the battery is fully charged.
storcli /c
x
/bbu show
storcli /c
x
/bbu show all
storcli /c
x
/bbu set autolearnmode=<
value
>
storcli /c
x
/bbu set bbuMode=<
value
>
storcli /c
x
/bbu set learndelayinterval=<
value
>
storcli /c
x
/bbu set powermode=sleep
storcli /c
x
/bbu set writeaceess=sealed
storcli /c
x
/bbu set learnStartTime=[DDD HH|off]
storcli /c
x
/bbu show modes
storcli /c
x
/bbu show properties
storcli /c
x
/bbu show status
storcli /c
x
/bbu start learn
storcli /c
x
/bbu start retentiontest
The detailed description for each command follows.
storcli /c
x
/bbu show
This command shows the summary information for the BBU of a controller.
Input example:
storcli /c0/bbu show
storcli /c
x
/bbu show all
This command shows all the information of the BBU.
Input example:
storcli /c0/bbu show all
storcli /c
x
/bbu set autolearnmode=<value>
This command starts the automatic learn cycle on the battery. The possible values are
0
- Enabled,
1
- Disabled, and
2
- WarnViaEvent.
Input example:
storcli /c0/bbu set autolearnmode=0
storcli /c
x
/bbu set bbuMode=<
value
>
This command sets the BBU mode for the BBU. The following table shows the various BBU modes: