LSI Corporation
- 359 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0058
Information
Format complete on %s
Logged when Format has completed.
0x0059
Information
Format started on %s
Logged when format unit is started on a PD.
0x005a
Critical
Hot Spare SMART polling failed on
%s (Error %02x)
Currently not logged.
0x005b
Information
Drive inserted: %s
Logged when drive is inserted and slot/enclosure fields of PD
are updated.
0x005c
Warning
Drive %s is not supported
Logged when the drive is not supported; reason could be the
number of drive has exceeded the MAX supported drives or
an unsupported drive is inserted like a SATA drive in SAS only
enclosure or could be a unsupported drive type.
0x005d
Warning
Patrol Read corrected medium error
on %s at %lx
Logged when Patrol read has successfully completed
recovery read and recovered data.
0x005e
Progress
Patrol Read progress on %s is %s
Logs patrol read progress, the progress is logged only if the
progress is greater than 1% at an interval of every 15 seconds.
0x005f
Fatal
Patrol Read found an uncorrectable
medium error on %s at %lx
Logged when Patrol read is unable to recover data.
0x0060
Critical
Predictive failure: CDB: %s
Logged when a failure is found during smart (predictive
failure) poll.
0x0061
Fatal
Patrol Read puncturing bad block on
%s at %lx
Logged when patrol read punctures a block due to
unrecoverable medium error.
0x0062
Information
Rebuild aborted by user on %s
Logged when the user aborts a rebuild operation.
0x0063
Information
Rebuild complete on %s
Logged when the rebuild operation on a logical drive on a
physical drive (which may have multiple LDs) is completed.
0x0064
Information
Rebuild complete on %s
Logged when rebuild operation is completed for all logical
drives on a given physical drive.
0x0065
Critical
Rebuild failed on %s due to source
drive error
Logged if one of the source drives for the rebuild operation
fails or is removed.
0x0066
Critical
Rebuild failed on %s due to target
drive error
Logged if the target rebuild drive (on which rebuild
operation is going on) fails or is removed from the controller.
0x0067
Progress
Rebuild progress on %s is %s
Logged to indicate the progress (in percentage) of the
rebuild operation on a given physical drive.
0x0068
Information
Rebuild resumed on %s
Logged when the rebuild operation on a physical drive
resumes.
0x0069
Information
Rebuild started on %s
Logged when the rebuild operation is started on a physical
drive.
0x006a
Information
Rebuild automatically started on %s Logged when the rebuild operation kicks in on a spare.
0x006b
Critical
Rebuild stopped on %s due to loss of
cluster ownership
Logged when the rebuild operation is stopped due to loss of
ownership.
0x006c
Fatal
Reassign write operation failed on
%s at %lx
Logged when a check condition or medium error is
encountered for a reassigned write.
0x006d
Fatal
Unrecoverable medium error during
rebuild on %s at %lx
Logged when the rebuild I/O encounters an unrecoverable
medium error.
0x006e
Information
Corrected medium error during
recovery on %s at %lx
Logged when recovery completed successfully and fixed a
medium error.
0x006f
Fatal
Unrecoverable medium error during
recovery on %s at %lx
Logged when the recovery for a failed I/O encounters a
medium error.
0x0070
Information
Drive removed: %s
Logged when a drive is removed from the controller.
Number
Severity
Level
Event Text
Generic Conditions when Each Event Occurs
Содержание ThinkServer RD650