LSI Corporation
- 356 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0009
Information
Background initialization rate
changed to %d%%
Logged to display background initialization progress
indication in percentage.
0x000a
Fatal
Controller cache discarded due to
memory/battery problems
Logged on cache discard due to hardware problems.
0x000b
Fatal
Unable to recover cache data due to
configuration mismatch
Currently not logged.
0x000c
Information
Cache data recovered successfully
Logged when cache data is successfully recovered after
reboot.
0x000d
Fatal
Controller cache discarded due to
firmware version incompatibility
Logged when cache data discarded because of firmware
version mismatch.
0x000e
Information
Consistency Check rate changed to
%d%%
Logged to display Consistency check progress indication
percentage.
0x000f
Fatal
Fatal firmware error: %s
Logged in case of fatal errors and also while entering debug
monitor.
0x0010
Information
Factory defaults restored
Logged while controller is reset to factory defaults.
0x0011
Information
Flash downloaded image corrupt
Logged to inform downloaded flash image is corrupt.
0x0012
Critical
Flash erase error
Logged in case of flash erase failure, generally after flash
update.
0x0013
Critical
Flash timeout during erase
Logged to indicate flash erase operation timed out.
0x0014
Critical
Flash error
Generic unknown internal error during flash update flash.
0x0015
Information
Flashing image: %s
Logged to display flash image name string before getting
updated to controller.
0x0016
Information
Flash of new firmware images
complete
Logged to inform successful update of flash image(s).
0x0017
Critical
Flash programming error
Logged to notify, write failure during flash update, not being
allowed usually due to internal controller settings.
0x0018
Critical
Flash timeout during programming
Logged to indicate flash write operation timed out.
0x0019
Critical
Flash chip type unknown
Logged during flash update tried with unsupported flash
chip type.
0x001a
Critical
Flash command set unknown
Logged while unsupported flash command set detected,
most likely because of unsupported flash chip.
0x001b
Critical
Flash verify failure
Logged when compare operation fails between written flash
data and original data.
0x001c
Information
Flush rate changed to %d seconds
Logged to notify modified cache flush frequency in seconds.
0x001d
Information
Hibernate command received from
host
Logged to inform about reception of hibernation command
from host to controller, generally during host shutdown.
0x001e
Information
Event log cleared
Logged when controller log has been cleared.
0x001f
Information
Event log wrapped
Logged when controller log has been wrapped around, when
the maximum logs are written.
0x0020
Fatal
Multi-bit ECC error: ECAR=%x,
ELOG=%x, (%s)
Logged to notify ECC multi bit error in memory, ELOG: ecc
info (source, type, syndrome), ECAR:ecc address.
0x0021
Warning
Single-bit ECC error: ECAR=%x,
ELOG=%x, (%s)
Logged to notify ECC single bit error in memory, ELOG: ecc
info (source, type, syndrome), ECAR:ecc address.
0x0022
Fatal
Not enough controller memory
Logged to notify fatal controller condition, when you run out
of memory to allocate.
0x0023
Information
Patrol Read complete
Logged when patrol read completes.
0x0024
Information
Patrol Read paused
Logged when patrol read is paused.