LSI Corporation
- 368 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0136
Information
Drive security key from escrow,
verified
Logged when controller lock key is verified from escrow.
0x0137
Information
Drive security key changed
Logged when controller lock key is re-keyed.
0x0138
Warning
Drive security key, re-key operation
failed
Logged when controller lock re-key operation failed.
0x0139
Warning
Drive security key is invalid
Logged when the controller lock is not valid.
0x013a
Information
Drive security key destroyed
Logged when the controller lock key is destroyed.
0x013b
Warning
Drive security key from escrow is
invalid
Logged when the controller escrow key is not valid. This
escrow key can not unlock any drive.
0x013c
Information
VD %s is now secured
Logged when secure LD is created.
0x013d
Warning
VD %s is partially secured
Logged when all the drives in the array are not secure.
0x013e
Information
PD %s security activated
Logged when PD security key is set.
0x013f
Information
PD %s security disabled
Logged when security key is removed from an FDE drive.
0x0140
Information
PD %s is reprovisioned
Logged when PD security is cleared.
0x0141
Information
PD %s security key changed
Logged when PD lock key is re-keyed.
0x0142
Fatal
Security subsystem problems
detected for PD %s
Logged when PD security can not be set.
0x0143
Fatal
Controller cache pinned for missing
or offline VD %s
Logged when LD cache is pinned.
0x0144
Fatal
Controller cache pinned for missing
or offline VDs: %s
Logged when pinned cache is found during OCR.
0x0145
Information
Controller cache discarded by user
for VDs: %s
Logged when LD pinned cache is discarded by the user.
0x0146
Information
Controller cache destaged for VD %s Logged when LD pinned cache is recovered.
0x0147
Warning
Consistency Check started on an
inconsistent VD %s
Logged when consistency check is started on an inconsistent
LD.
0x0148
Warning
Drive security key failure, cannot
access secured configuration
Logged when an invalid lock key is detected.
0x0149
Warning
Drive security password from user is
invalid
Not logged.
0x014a
Warning
Detected error with the remote
battery connector cable
Not logged.
0x014b
Information
Power state change on PD %s from
%s to %s
Logged when PD power state (spun up, spun down,
in-transition) changes.
0x014c
Information
Enclosure %s element (SES code
0x%x) status changed
Not logged.
0x014d
Information
PD %s rebuild not possible as
HDD/CacheCade software mix is not
supported in a drive group
Logged when mixing violation occurs due to HDD/SSD
mismatch.
0x014e
Information
Replace Drive cannot be started on
PD %s from %s, as HDD/CacheCade
software mix is not supported in a
drive group
Logged when Replace could not be started on a PD because
HDD/CacheCade software mix was not supported in a drive
group.
0x014f
Information
VD bad block table on %s is cleared
Logged when a VD bad block table was cleared.
0x0150
Caution
SAS topology error: 0x%lx
Logged when a SAS topology error occurred.
0x0151
Information
VD cluster of medium errors
corrected for %s at %lx (on %s at %lx)
Logged when medium errors were corrected for a PD for a
LD.
Number
Severity
Level
Event Text
Generic Conditions when Each Event Occurs