LSI Corporation
- 75 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 4: Ctrl-R Utility
Converting JBOD Drives to Unconfigured Good Drives
Figure 48 Manage Preserved Cache
3.
Press
Discard Cache
to discard the preserved cache from the virtual drive. A message box appears, asking you to
confirm your choice.
4.
Press
OK
to continue.
4.11
Converting JBOD Drives to Unconfigured Good Drives
You can convert multiple JBODs to Unconfigured Good drives (from the
VD Mgmt
screen) or you can convert a
particular JBOD drive to an Unconfigured Good drive (from the
Drive Management
screen).
NOTE
The MegaRAID SAS 9240-4i and the MegaRAID SAS 9240-8i controllers
support JBOD.
Perform the following steps to convert multiple JBODs to Unconfigured Good drives:
1.
In the
VD Mgmt
screen, navigate to the controller, and press the F2 key.
2.
Navigate to
Make Unconfigured Good
, and press Enter.
The
Convert JBOD to Unconfigured Good
dialog appears, which shows all JBODs available in the system.