LSI Corporation
- 315 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 11: Maintaining and Managing Storage Configurations
Running a Consistency Check
To run a consistency check, first set the consistency check properties, and then schedule the consistency check. This
section explains how to set the properties, schedule the check, and run the consistency check.
11.2.1
Setting the Consistency Check Settings
Follow these steps to set the properties for a consistency check:
1.
Click the
Physical
tab or the
Logical
tab and select a controller.
2.
Click
Go To > Controller > Set Consistency Check Properties
.
The
Set Consistency Check Properties
dialog appears.
Figure 197 Set Consistency Check Properties Dialog
3.
Choose one of the two options:
—
Stop Consistency Check on Error
: The RAID controller stops the consistency check operation if the utility
finds an error.
—
Continue Consistency Check and Fix Errors
: The RAID controller continues the consistency check if the
utility finds and error, and then fixes the errors.
4.
Click
Ok
.
11.2.2
Scheduling a Consistency Check
Follow these steps to set the properties for a consistency check:
1.
Click the
Physical
tab or the
Logical
tab, and select the controller.
2.
Select
Go To > Controller > Schedule Consistency Check
.
The
Schedule Consistency Check
dialog appears.