LSI Corporation
- 84 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 4: Ctrl-R Utility
Viewing and Changing Device Properties
Figure 55 Manage Link Speed
—
The
SAS Address
column shows the SAS address that uniquely identifies a device in the SAS domain.
—
The
Phy
column shows the system-supported phy link values. The phy link values are from 0 through 7.
—
The
Link Speed
column shows the phy link speeds.
3.
Select the desired link speed by using the drop-down list.
The link speed values are Auto,1.5Gb/s, 3Gb/s, 6Gb/s, or 12Gb/s.
NOTE
By default, the link speed in the controller is
Auto
or the value last
saved by you.
4.
Press
OK
.
A message box appears, asking you to restart your system for the changes to take effect.
5.
Press
OK
.
The link speed value is now reset. The change takes place after you restart the system.
4.13.9
Managing Power Save Settings for the Controller
You can change the controller’s power-save settings by using the Dimmer Switch enhancement (Power-Save mode).
Perform the following steps to change the power save settings:
1.
Navigate to the second
Controller Settings
screen.
2.
Navigate to
Manage Power Save
, and press Enter.
The
Manage Power Save
dialog appears,.