LSI Corporation
- 101 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 5: The HII Configuration Utility
Managing Configurations
6.
If protection is enabled, highlight the
Protect Virtual Drive
.
This field is not available unless the protection feature is already supported by the controller.
7.
Highlight the
Select Drives From
field, press Enter, and select
Unconfigured Capacity
or
Free Capacity
.
Free capacity
means the new virtual drive is created from unused (free) drive capacity that is already part of a
virtual drive.
Unconfigured capacity
means the new virtual drive is created on previously unconfigured drives.
8.
Highlight the
Virtual Drive Name
field, press Enter, and enter a name for the new virtual drive.
9.
(Optional) Change the
Virtual Drive Size Unit
value by highlighting this field, pressing Enter, and selecting a
value from the pop-up menu.
The options are
MB
,
GB
, and
TB
.
10. (Optional) Change the default values for
Strip Size
,
Read Policy
,
Write Policy
,
I/O Policy
,
Access Policy
,
Drive
Cache
,
Disable Background Initialization
, and
Default Initialization
.
See
for descriptions of these options.
11. Highlight
Select Drives
and press Enter.
The following dialog appears.
Figure 68 Select Drives Window
Follow these steps to select physical drives for the new virtual drive.
1.
(Optional) Change the default
Select Media Type
by highlighting this field, pressing Enter, and selecting an
option from the pop-up menu.
The choices are
HDD
and
SSD
. Combining HDDs and SSDs in a single virtual drive is not supported.
2.
(Optional) Change the default
Select Interface Type
by highlighting this field, pressing Enter, and selecting an
option from the pop-up menu.
The choices are
SAS
,
SATA
, and
Both
. Depending on the configuration of your system, combining SAS and SATA
drives in a virtual drive might not be supported.
3.
Select physical drives for the virtual drive by highlighting each drive and pressing the spacebar to select it. A small
red arrow at the bottom of the window indicates you can scroll down to view more drives.
NOTE
The red arrow appears when there is too much information to display
in one dialog. The amount of information that can be displayed in one
dialog depends on the capabilities of the HII browser.
Содержание ThinkServer RD650
Страница 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Страница 417: ......
Страница 418: ......