LSI Corporation
- 364 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x00cf
Information
Enclosure %s Power supply %d cable
inserted
Logged when the enclosure services process has detected
that the Enclosure Power supply cable is inserted and it was
removed earlier.
0x00d0
Information
Enclosure %s Fan %d returned to
normal
Logged when the enclosure services process has detected
that the current status of a fan is good and it was failed
earlier.
0x00d1
Information
BBU Retention test was initiated on
previous boot
Logged when the Battery Retention test was initiated on
previous boot.
0x00d2
Information
BBU Retention test passed
Logged when the Battery Retention test passed successfully.
0x00d3
Critical
BBU Retention test failed!
Logged when the Battery Retention test failed.
0x00d4
Information
NVRAM Retention test was initiated
on previous boot
Logged when the NVRAM Retention test was initiated on
previous boot.
0x00d5
Information
NVRAM Retention test passed
Logged when the NVRAM Retention test passed successfully.
0x00d6
Critical
NVRAM Retention test failed!
Logged when the NVRAM Retention test failed.
0x00d7
Information
%s test completed %d passes
successfully
Logged when the controller diagnostics test passes
successfully.
0x00d8
Critical
%s test FAILED on %d pass. Fail data:
errorOffset=%x goodData=%x
badData=%x
Logged when the controller diagnostics test fails.
0x00d9
Information
Self check diagnostics completed
Logged when Self check diagnostics is completed.
0x00da
Information
Foreign Configuration detected
Logged when Foreign Configuration is detected.
0x00db
Information
Foreign Configuration imported
Logged when Foreign Configuration is imported.
0x00dc
Information
Foreign Configuration cleared
Logged when Foreign Configuration is cleared.
0x00dd
Warning
NVRAM is corrupt; reinitializing
Logged when NVRAM is corrupt and re-initialized.
0x00de
Warning
NVRAM mismatch occurred
Logged when NVRAM mismatch occurs.
0x00df
Warning
SAS wide port %d lost link on PHY
%d
Logged when SAS wide port lost link on a PHY.
0x00e0
Information
SAS wide port %d restored link on
PHY %d
Logged when a SAS wide port restored link on a PHY.
0x00e1
Warning
SAS port %d, PHY %d has exceeded
the allowed error rate
Logged when a SAS PHY on port has exceeded the allowed
error rate.
0x00e2
Warning
Bad block reassigned on %s at %lx to
%lx
Logged when a Bad block is reassigned on a drive from a
error sector to a new sector.
0x00e3
Information
Controller Hot Plug detected
Logged when a Controller Hot Plug is detected.
0x00e4
Warning
Enclosure %s temperature sensor %d
differential detected
Logged when an Enclosure temperature sensor differential is
detected.
0x00e5
Information
Drive test cannot start. No qualifying
drives found
Logged when Disk test cannot start. No qualifying disks
found.
0x00e6
Information
Time duration provided by host is
not sufficient for self check
Logged when Time duration provided by the host is not
sufficient for self check.
0x00e7
Information
Marked Missing for %s on drive
group %d row %d
Logged when a physical drive is Marked Missing on an array
at a particular row.
0x00e8
Information
Replaced Missing as %s on drive
group %d row %d
Logged when a physical drive is Replaced Missing on an array
at a particular row.
0x00e9
Information
Enclosure %s Temperature %d
returned to normal
Logged when an Enclosure temperature returns to normal.
Number
Severity
Level
Event Text
Generic Conditions when Each Event Occurs