LSI Corporation
- 164 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 6: StorCLI
Working with the Storage Command Line Tool
6.6.2.2
Controller Show Commands
The Storage Command Line Tool supports the following show commands:
storcli /c
x
show
storcli /c
x
show all
storcli /c
x
show freespace
dimmerswitch|ds
See
See
foreignautoimport
on|off
Imports foreign configuration automatically, at
boot.
jbod
on|off
Enables/disables JBOD mode; by default, drives
become system drives.Not supported by all
controllers.
loadbalancemode
on|off
Enables/disables automatic load balancing
between SAS phys or ports in a wide port
configuration.
maintainpdfailhistory
on|off
Maintains the physical drive fail history.
migraterate
0 to 100
Sets data migration rate in percentage.
patrolread|pr
See
See
perfmode
0
: Tuned to provide best IOPS, currently
applicable to non-FastPath
1
: Tuned to provide least latency, currently
applicable to non-FastPath
Performance tuning setting for the controller.
pi
on|off
Enables/disables data protection on the
controller.
pi import
on|off
Enables/disables import data protection drives
on the controller.
prcorrectunconfiguredareas
on|off
Correct media errors during PR by writing 0s to
unconfigured areas of the disk.
prrate
0 to 100
Sets patrol read rate of the virtual drives in
percentage.
rebuildrate
0 to 100
Sets rebuild rate of the drive in percentage.
reconrate
0 to 100
Sets reconstruction rate for a drive in percentage.
restorehotspare
on|off
Becomes a hot spare on insertion of a failed
drive.
smartpollinterval
0 to 65535
Set time for polling of SMART errors in seconds.
spinupdrivecount
0 to 255
Sets number of drives that are spun up at a time.
spinupdelay
0 to 255
Sets spin-up delay between a group of drives or a
set of drives, in seconds.
stoponerror
on|off
Stops the MegaRAID BIOS during POST, if any
errors are encountered.
time
Valid time in
yymmdd hh:mm:ss
format
or
systemtime
Sets the controller time to your input value or the
system time (local time in 24-hour format).
usefdeonlyencrypt
on|off
Enables/disables FDE drive-based encryption.
DPM
on|off
Enables/disables drive performance monitoring
supportssdpatrolread
on|off
Enables/disables patrol read for SSD drives.
SGPIOforce
on|off
Force SGPIO status per port only for four drives;
affects HPC controllers.
Property Name
Set Command Range
Description
Содержание ThinkServer RD650