LSI Corporation
- 58 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 4: Ctrl-R Utility
Creating a Storage Configuration
Figure 30 Create a New Virtual Drive
NOTE
If your system detects any JBODs the
Convert JBOD to Unconfigured
Good
dialog (
on page
) appears before the
Create New
VD
dialog. The
Convert JBOD to Unconfigured Good
dialog lets you
convert the JBODs to Unconfigured Good.
3.
Select a RAID level for the drive group from the
RAID Level
field.
4.
Select a power save mode for the drive group from the
Power save mode
field. The options available are
Auto
,
Max
, and
Controller defined
.
This field is enabled only if power saving on configured drives is supported on the controller.
Power Save (Dimmer Switch feature) is a technology that conserves energy by placing certain unused drives into
a Power Save mode. In Power-Save mode, the drives use less energy. The fan and the enclosure require less
energy to cool and house the drives, respectively. Also, this technology helps avoid application time-outs caused
by spin-up delays and drive wear caused by excessive spin-up/down cycles.
5.
You can encrypt data and use drive-based key management for your data security solution. This option protects
the data in the event of theft or loss of drives. Select a value from the
Secure VD
field. The options available are
Yes
and
No
.
6.
You can choose whether you want to use the data protection feature on the newly created virtual drive. Select a
value from the
Data Protection
field. The options available are
Yes
and
No
. The
Data Protection
field is enabled
only if the controller has data protection physical drives connected to it.
7.
You can change the sequence of the physical drives in the
Drives
box. All the available unconfigured good drives
appear in the
Drives
box. Select the physical drives in the sequence that you prefer. Based on your selection, the
sequence number appears in the
#
column.
8.
You can enter a size lesser than the maximum size of the drive group, if you want to create other virtual drives on
the same drive group. The maximum size of the drive group appears in the
Size
field. The size entered can be in
MB, GB, or TB.
9.
Enter a name for the virtual drive in the
Name
field. The name given to the virtual drive cannot exceed 15
characters.