LSI Corporation
- 391 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix C: MegaCLI Commands to StorCLI Command Conversion
Battery Commands
C.5
RAID Configuration Commands
Table 74 RAID Configuration Commands
Description
MegaCLI Command
StorCLI Command
Create a RAID configuration of
RAID type 0, 1, 5, and 6.
MegaCli –CfgLDAdd
-R0|-R1|-R5|-R6[E0:S0,E1:S1,...]
[WT | WB] [NORA | RA | ADRA]
[Direct | Cached]
[CachedBadBBU|NoCachedBadBBU]
[-sz
XXXXXXXX
[-sz
YYYYYYYY
[... ]]]
[-strpszM] [–Hsp[E5:S5,...]]
[–afterLdX] -aN
storcli /c
x
add vd type=raid[0|1|5|6]
[Size=<
VD1_Sz
>,<
VD2_Sz
>,..|*all]
[name=<
VDNAME1
>,..]
drives=
e
:
s
|
e
:
s
-
x
|
e
:
s
-
x
,
y
;
e
:
s
-
x
,
y
,
z
[PDpe
rArray=
x
]
[SED] [pdcache=on|off|*default][pi]
[DimmerSwitch(ds)=default|automatic(auto
)|*none|maximum(max)
|MaximumWithoutCaching(maxnocache)]
[wt|*wb|awb] [nora|*ra] [*direct|cached]
[strip=<8|16|32|64|128|256|512|1024]
[AfterVd=
X
]
[Spares=[
e
:]
s
|[
e
:]
s
-
x
|[
e
:]
s
-
x
,
y
] [force]
Create a CacheCade virtual drive.
MegaCLI -CfgCacheCadeAdd [-rX]
-Physdrv[E0:S0,...] {-Name
LdNamestring} [WT|WB|ForcedWB]
[-assign -LX|L0,2,5..|LALL]
-aN|-a0,1,2|-Aall
storcli /c
x
add vd cachecade|cc
Type=raid[0,1,10]
drives=[
e
:]
s
|[
e
:]
s
-
x
|[
e
:]
s
-
x
,
y
[ < WT|
WB> ] [assignvds=0,1,2]
e
:]
Create a RAID configuration of
RAID type 10, 50, and 60.
MegaCli –CfgSpanAdd
-aN|-a0,1,2|-aALL -R10|-R50|R60
–Array0[E0:S0,E1:S1,...]
–Array1[E0:S0,E1:S1,...] [...] [WT
| WB] [NORA | RA | ADRA] [Direct |
Cached]
[CachedBadBBU|NoCachedBadBBU]
[-sz
XXXXXXXX
[-sz
YYYYYYYY
[... ]]]
[-strpszM] [–afterLdX] -aN
storcli /c
x
add vd type=raid[10|50|60]
[Size=<
VD1_Sz
>,<
VD2_Sz
>,..|*all] [name=<
VDNAME1
>,..]
drives=
e
:
s
|
e
:
s
-
x
|
e
:
s
-
x
,
y
;
e
:
s
-
x
,
y
,
z
[PDpe
rArray=
x
]
[SED] [pdcache=on|off|*default][pi]
[DimmerSwitch(ds)=default|automatic(auto
)|*none|maximum(max)
|MaximumWithoutCaching(maxnocache)]
[wt|*wb|awb] [nora|*ra] [*direct|cached]
[strip=<8|16|32|64|128|256|512|1024]
[AfterVd=
X
]
[Spares=[
e
:]
s
|[
e
:]
s
-
x
|[
e
:]
s
-
x
,
y
] [force]
Clear the complete configuration.
MegaCli -CfgClr [-Force]
-aN|-a0,1,2|-aALL
storcli /c
0
/vall delete [force]
Show the topology information
of the drive group.
MegaCLI -CfgDsply
-aN|-a0,1,2|-Aall
storcli /c
x
/dall show [all]
Show information for a
CacheCade virtual drive.
MegaCLI -CfgCacheCadeDsply
-aN|-a0,1,2|-Aall
storcli /c
x
/dall show CacheCade(cc)
Delete a virtual drive hosting the
operating system.
MegaCLI -CfgLdDel
-LX|-L0,2,5...|-LALL [-Force]
-aN|-a0,1,2|-aALL
storcli /c
x
/v/v
x
[all] delete -force
Delete a CacheCade virtual drive.
MegaCLI -CfgCacheCadeDel
-LX|-L0,2,5...|-LALL
-aN|-a0,1,2|-Aall
storcli /c
x
/v
x
[all] delete
CacheCade(cc)
Show, delete, and import the
foreign configuration commands.
MegaCli –CfgForeign –Scan |
{-Preview | –Dsply| -Import |
-Clear[FID]} -aN|-a0,1,2|-aALL"
storcli /c
x
/f(
x
|all) show [all]
[securityKey=
xxx
]
storcli /c
x
/f(
x
|all) del|delete
[securityKey=
xxx
]
storcli /c
x
/f(
x
|all) import [preview]
[securityKey=
xxx
]"
Содержание ThinkServer RD650
Страница 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Страница 417: ......