March 2014
Chapter 6: StorCLI
Working with the Storage Command Line Tool
Table 36 Verbs in the StorCli Command Syntax
<[adverb | attributes | properties] >
– Specifies what the verb modifies or displays.
<[key=value]>
– Specifies a value, if a value is required by the command.
6.6
Working with the Storage Command Line Tool
This section describes the commands supported by the Storage Command Line Tool.
NOTE
The Storage Command Line Tool is not case sensitive.
CAUTION
The order in which you specify the command options should be the
same as in the User Guide; otherwise, the command will fail.
NOTE
The Storage Command Line Tool does not support the Snapshot
feature.
6.6.1
System Commands
6.6.1.1
System Show Commands
The Storage Command Line Tool supports the following system show commands:
storcli show
storcli show all
storcli show ctrlcount
storcli show help
storcli -v
Verbs
Description
add
This verb adds virtual drives, JBODs, and so on to the object identifier.
del
This verb deletes a drive, value, or property of the object identifier.
set
This verb sets a value of the object identifier.
show
This verb shows the value and properties of the object identifier.
pause
This verb pauses an ongoing operation.
resume
This verb resumes paused operation.
compare
This verb compares an input value with a system value.
download
This verb downloads and flashes a file to the target.
start
This verb starts an operation.
flush
This verb flushes a controller cache or a drive cache.
stop
This verb stops an operation that is in progress. A stopped process cannot be resumed.
import
This verb imports the foreign configuration into the drive.
expand
This verb expands the size of the virtual drive.
insert
This verb replaces the configured drive that is identified as missing, and starts an automatic rebuild.
flasherase
This verb erases the flash memory on the controller.
transform
This verb downgrades the firmware memory on the controller.
restart
This verb restarts the controller without a system reboot.
apply
This verb applies the activation Key to a WarpDrive card.