LSI Corporation
- 366 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0107
Warning
Foreign configuration table overflow Logged when the number of GUIDs to import exceeds the
total supported by the firmware.
0x0108
Warning
Partial foreign configuration
imported, PDs not imported:%s
Logged when all the foreign configuration drives could not
be imported.
0x0109
Information
Connector %s is active
Logged during initial boot when a SAS MUX connector is
found for the controller.
0x010a
Information
Board Revision %s
Logged during boot.
0x010b
Warning
Command timeout on PD %s,
CDB:%s
Logged when command to a PD Timesout.
0x010c
Warning
PD %s reset (Type %02x)
Logged when PD is reset.
0x010d
Warning
VD bad block table on %s is 80% full Logged when number of Bad Blocks entries is at 80 % of what
can be supported in the firmware.
0x010e
Fatal
VD bad block table on %s is full;
unable to log block %lx (on %s at
%lx)
Logged when number of Bad Blocks exceed what can be
supported in the firmware.
0x010f
Fatal
Uncorrectable medium error logged
for %s at %lx (on %s at %lx)
Logged when an uncorrectable medium error is detected.
0x0110
Information
VD medium error corrected on %s at
%lx
Logged on the corrected medium error.
0x0111
Warning
Bad block table on PD %s is 100% full Logged when Bad block table is 100 % Full. Any more media
errors on this physical drive will not be logged in the bad
block table.
0x0112
Warning
VD bad block table on PD %s is 100%
full
Logged when Bad block table is 100 % Full. Any more media
errors on this logical drive will not be logged in the bad block
table.
0x0113
Fatal
Controller needs replacement, IOP is
faulty
Currently not logged in the firmware.
0x0114
Information
Replace Drive started on PD %s from
PD %s
Logged when Replace is started.
0x0115
Information
Replace Drive aborted on PD %s and
src is PD %s
Logged when Replace is aborted.
0x0116
Information
Replace Drive complete on PD %s
from PD %s
Logged when Replace is completed.
0x0117
Progress
Replace Drive progress on PD %s is
%s
Logged to provide the progress of Replace.
0x0118
Information
Replace Drive resumed on PD %s
from %s
Logged when Replace operation is resumed.
0x0119
Information
Replace Drive automatically started
on PD %s from %s
Logged on automatic start of Replace.
0x011a
Critical
Replace Drive failed on PD %s due to
source %s error
Logged when the source physical drive of a Replace fails. The
Replace stops and rebuild starts on the destination physical
drive.
0x011b
Warning
Early Power off warning was
unsuccessful
Currently not logged in the firmware.
0x011c
Information
BBU FRU is %s
Logged only for IBM.
0x011d
Information
%s FRU is %s
Logged if FRU data is present. Logged only for IBM.
0x011e
Information
Controller hardware revision ID %s
Currently not used in the firmware.
Number
Severity
Level
Event Text
Generic Conditions when Each Event Occurs
Содержание ThinkServer RD650
Страница 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Страница 417: ......
Страница 418: ......