LSI Corporation
- 358 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x003f
Warning
Consistency Check found
inconsistent parity on %s at strip %lx
Logged when consistency check finds inconsistency parity
on a strip.
0x0040
Warning
Consistency Check inconsistency
logging disabled on %s (too many
inconsistencies)
Logged when consistency check finds too many inconsistent
parity (greater than 10) and the inconsistency parity logging
is disabled.
0x0041
Progress
Consistency Check progress on %s is
%s
Logs Consistency Check progress, the progress is logged only
if the progress is greater than 1% at an interval of every
15 seconds.
0x0042
Information
Consistency Check started on %s
Logged when consistency check has started
0x0043
Warning
Initialization aborted on %s
Logged when consistency check is aborted by you or for
some other reason.
0x0044
Critical
Initialization failed on %s
Logged when initialization has failed.
0x0045
Progress
Initialization progress on %s is %s
Logs initialization progress, the progress is logged only if the
progress is greater than 1% at an interval of every
15 seconds.
0x0046
Information
Fast initialization started on %s
Logged when quick initialization has started on a LD. The
parameter to decide Quick init or Full init is passed by you.
0x0047
Information
Full initialization started on %s
Logged when full initialization has started.
0x0048
Information
Initialization complete on %s
Logged when initialization has completed successfully.
0x0049
Information
LD Properties updated to %s (from
%s)
Logged when LD properties has been changed.
0x004a
Information
Reconstruction complete on %s
Logged when reconstruction has completed successfully.
0x004b
Fatal
Reconstruction of %s stopped due to
unrecoverable errors
Logged when reconstruction has finished because of failure
(unrecoverable errors).
0x004c
Fatal
Reconstruct detected uncorrectable
double medium errors (%s at %lx on
%s at %lx)
Logged while reconstructing if an unrecoverable double
medium error is encountered.
0x004d
Progress
Reconstruction progress on %s is %s Logs reconstruction progress, the progress is logged only if
the progress is greater than 1% at an interval of every
15 seconds.
0x004e
Information
Reconstruction resumed on %s
Logged when reconstruction resumes after a power cycle.
0x004f
Fatal
Reconstruction resume of %s failed
due to configuration mismatch
Logged when reconstruction resume failed due to
configuration mismatch.
0x0050
Information
Reconstruction started on %s
Logged on start of reconstruction on a LD.
0x0051
Information
State change on %s from %s to %s
Logged when there is change in LD state. The event gives the
new and old state. The state could be one of the following,
LDS_OFFLINE, LDS_PARTIALLY_DEGRADED, LDS_DEGRADED,
LDS_OPTIMAL.
0x0052
Information
Drive Clear aborted on %s
Logged when PD clear is aborted.
0x0053
Critical
Drive Clear failed on %s (Error %02x) Logged when drive clear is failed and the even is logged
along with error code.
0x0054
Progress
Drive Clear progress on %s is %s
Logs drive clear progress, the progress is logged only if the
progress is greater than 1% at an interval of every 15 seconds.
0x0055
Information
Drive Clear started on %s
Logged when drive clear started on a PD.
0x0056
Information
Drive Clear completed on %s
Logged when PD clear task is completed successfully on a PD.
0x0057
Warning
Error on %s (Error %02x)
Logged if Read returns with Uncorrectable error or same
errors on both the drives or write long returns with an error
(ie. puncture operation could failed).
Number
Severity
Level
Event Text
Generic Conditions when Each Event Occurs