LSI Corporation
- 144 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 5: The HII Configuration Utility
Managing Physical Drives
5.
Highlight
Replace Drive
and press Enter.
A success message appears, and the replacement process begins as the data on the drive is rebuilt on the
replacement drive.
6.
Click
OK
.
You are returned to the
Drive Management
menu. The status of the drive changes from
Online
to
Replacing
.
You can perform other tasks in the HII utility while the replacement operation runs.
5.6.1.4
Placing a Drive Offline
Perform these steps to force a physical drive offline. If you perform this operation on a good drive that is part of a
redundant virtual drive with a hot spare, the drive rebuilds to the hot spare drive. The drive you force offline goes into
the Unconfigured Bad state.
1.
Open the pop-up drive operations menu, highlight
Place Drive Offline
, and press Enter.
2.
Highlight
Go
, which appears beneath
Operation
, and press Enter.
The Place Drive Offline message appears.
3.
Highlight
Confirm
, and press the spacebar to confirm the operation.
4.
Highlight
Yes
, and press Enter.
The selected drive is forced offline.
5.6.1.5
Placing a Drive Online
Perform these steps to force a selected member drive of a virtual drive online after it been forced offline.
1.
Open the pop-up drive operations menu, highlight
Place Drive Online
, and press
Enter
.
2.
Highlight
Go
and press
Enter
.
The
Place Drive Online
warning appears.
CAUTION
Forcing a drive online that is part of a redundant array is
not
recommended.
3.
Highlight
Confirm
and press the spacebar to confirm the operation.
4.
Highlight
Yes
and press
Enter
.
A message appears indicating that the action has been completed.
5.
Highlight
Yes
and press
Enter
to return to the previous dialog.
The drive is now online.
5.6.1.6
Assigning a Global Hotspare Drive
Global hotspare drives provide protection to redundant virtual drives on the controller. If you select an Unconfigured
Good drive, you have the option to assign it as a global hotspare drive. Perform these steps to assign a global
hotspare.
1.
Open the pop-up drive operations menu, highlight
Assign Hot Spare Drive
, and press Enter.
2.
Highlight
Go
, which appears beneath
Operation
, and press Enter.
The hot spare selection dialog appears.
3.
Highlight
Assign Global Hot Spare Drive
and press Enter.
The status of the selected drive changes to hotspare.
NOTE
To refresh the status of the drive displayed in the dialog, exit back to
the
Main Menu
, and then re-enter the
Drive Management
dialog.