LSI Corporation
- 214 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 7: MegaRAID Storage Manager Overview and Installation
Installing MegaRAID Storage Manager
If the
.so
files are not present in the
/usr/lib
directory, create a link with the existing version of the library. For
example, if
libcrypto.so.6
is present and
libcrypto.so
is not, create the link as follows:
ln -s libcrypto.so.6 libcrypto.so.4
On a 64-bit operating system, the system libraries are present in the
/usr/lib64
directory by default. However, for
supporting CIM Plug-in, make sure that the libraries are also present in
/usr/lib
by installing the appropriate RPMs.
7.3.10.2
Executing a CIM Plug-in on Red Hat Enterprise Linux 5
To execute a Common Information Model (CIM) plug-in on Red Hat Enterprise Linux 5, you must create the following
symbolic links:
1.
cd /usr/lib
on RHEL 5
2.
Search for
libcrypto
,
libssl
, and
libsysfs
libraries as follows:
ls -lrt libcrypto*, ls -lrt libssl*, ls -lrt libsysfs*
3.
If the files
libcrypto.so.4
,
libssl.so.4
, and
libsysfs.so.1
are missing, manually create sym links as
follows:
ln -s libcrypto.so libcrypto.so.4
ln -s libssl.so libssl.so.4
ln -s libsysfs.so libsysfs.so.1
For more information about CIM, see
MegaRAID Storage Manager Support on the VMware ESXi Operating System
.
If the
.so
files are not present in the
/usr/lib
directory, create a link with the existing version of the library. For
example, if
libcrypto.so.6
is present and
libcrypto.so
is not, create the link as follows:
ln -s libcrypto.so.6 libcrypto.so.4
On a 64-bit operating system, the system libraries are present in the
/usr/lib64
directory by default. However, for
supporting CIM Plug-in, make sure that the libraries are also present in
/usr/lib
by installing the appropriate RPMs.
7.3.11
MegaRAID Storage Manager Software Customization
You can customize your Logo and Splash window by editing the
msm.properties
file present in the
<installation-directory\MegaRAID Storage Manager>
folder.
The
msm.properties
file has no values for the following keys:
CHANNELLOGO=
CHANNELSPLASHSCREEN=
No default values are assigned for these keys; therefore, the MegaRAID Storage Manager uses the default LSI Logo and
splash screen.
To customize the Logo and splash screen, enter the Logo and Splash screen file name against these entries.
To enter the file names follow these steps:
1.
Open the
msm.properties
file in the <
installation-directory\MegaRAID Storage Manager
>
folder.
2.
Enter the value for the logo file against the key CHANNELLOGO.
3.
Enter the value for the splash screen file against the key CHANNELSPLASHSCREEN.
4.
Save the file.
5.
Place these two images in the <
installation-directory
\MegaRAID Storage Manager
> folder.
6.
Start the application.
Following are some of important points that you need to keep in mind: