1AF
1-3-40
MSW
H
ICFM
DM
Dev. bias
300 ms
1000 ms
Stabilization drive start
temperature 167
°
C/332.6
°
F
Secondary stabilization fixing
temperature 175
°
C/347
°
F
Primary stabilization fixing
temperature 170
°
C/338
°
F
Copying enabled
Half
speed
Full speed
210 ms
200 ms
Fixing temperature control
Timing chart 1-3-7
Fixing temperature control
A
210 ms after the main switch (MSW) has been turned on, the fixing heater (H) turns on
to heat the heat roller.
B
300 ms after the main switch (MSW) has been turned on, the internal cooling fan motor
(ICFM) rotates at full speed for 1000 ms and then at half speed.
C
In low temperature mode, when the fixing temperature reaches 167°C/332.6°F, the drive
motor (DM) and developing bias turn on to start stabilization drive control.
D
When the fixing temperature reaches 170°C/338°F, primary stabilization is achieved.
Copying is enabled if the time from the main switch (MSW) being turned on has reached
the following:
1 s if the fixing temperature was 100°C/212°F or above when the main switch was turned
on;
43 s if the fixing temperature was between 13°C/55.4°F and 99°C/210.2°F and the
external temperature was 18°C/64.4°F or above when the main switch was turned on;
or
69 s in low temperature mode (the external temperature is below 20°C/68°F).
E
When copying is enabled in low temperature mode, the drive motor (DM) turns off and,
after 200 ms, the developing bias turns off to end stabilization drive control.
F
When the fixing temperature reaches 175°C/347°F, secondary stabilization is achieved,
and the fixing heater (H) is turned on and off as required to keep the fixing temperature
at 175°C/347°F.
Содержание DC-1560
Страница 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Страница 3: ...SERVICE MANUAL DC 1560 2050...
Страница 12: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 23: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...
Страница 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Страница 28: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Страница 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Страница 114: ...3 1 15 1AF Make test copies 1 Place paper in the paper drawer and make test copies Completion of machine installation...
Страница 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Страница 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...
Страница 229: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...