1AF
3-3-48
(3) Adjusting developing bias voltage (reference)
The developing bias voltage is factory-adjusted. Only perform the following adjustment
when carrier or background appears on the copy image after control VR202 on the high-
voltage transformer PCB has been turned accidentally.
Required adjustment tool
• Tester
Procedure
Start
Remove the 1-pin developing
bias connector from DB OUT
on the high-voltage transform-
er PCB, and apply the tester's
positive terminal to DB OUT.
Enter 31 with the numeric
keys.
Yes
No
Apply the tester's negative
terminal to an uncoated part
of the copier's frame.
Enter simulation mode.
Press the all clear/reset key.
Press the stop/clear key.
Does the devel-
oping bias voltage read the
specified value?
End
Turn control VR202 until the
specified value (280
±
5 V DC)
is reached.
Turn the control counterclockwise to decrease
the voltage and clockwise to increase it.
If developing bias is set below the specified level,
a dark background shows; if it is above the
specified level, the copy image is too light.
Press the all clear/reset key.
Exit simulation mode.
Press the print key.
Figure 3-3-46
DB OUT
VR 202
To ground
(uncoated part of the frame)
Tester
Positive
terminal
Negative terminal
1-pin connector
High-voltage
transformer PCB
Содержание DC-1560
Страница 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Страница 3: ...SERVICE MANUAL DC 1560 2050...
Страница 12: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 23: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...
Страница 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Страница 28: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Страница 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Страница 114: ...3 1 15 1AF Make test copies 1 Place paper in the paper drawer and make test copies Completion of machine installation...
Страница 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Страница 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...
Страница 229: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...