1AF
3-6-22
Terminals (CN)
Voltage
Remarks
1-9
4-3
24/0 V DC (pulse)
OPCB scan sink (DEG 0), output
1-10
4-3
24/0 V DC (pulse)
OPCB scan sink (DEG 1), output
1-11
4-3
24/0 V DC (pulse)
OPCB scan sink (DEG 2), output
1-12
4-3
24/0 V DC (pulse)
OPCB scan sink (DEG 3), output
1-13
4-3
24/0 V DC (pulse)
OPCB scan sink (DEG 4), output
1-14
4-3
24/0 V DC (pulse)
OPCB scan sink (DEG 5), output
1-15
4-3
24/0 V DC (pulse)
OPCB scan sink (DEG 6), output
1-16
4-3
24/0 V DC (pulse)
OPCB scan sink (DEG 7), output
1-17
4-3
0/5 V DC (pulse)
OPCB return (KEY 0), input
1-18
4-3
0/5 V DC (pulse)
OPCB return (KEY 1), input
1-19
4-3
0/5 V DC (pulse)
OPCB return (KEY 2), input
1-20
4-3
0/11.7 V DC
Developing bias on/off, output
1-21
4-3
0/15.9 V DC
Main charging on/off, output
1-22
4-3
0/15.9 V DC
Transfer charging on/off, output
1-23
4-3
0/24 V DC
Separation charging on/off, output
1-24
4-3
0 – 5 V DC
Grid control voltage, output
1-25
4-3
0 – 5 V DC
Main charging control voltage, output
1-26
4-3
0 – 5 V DC
Transfer charging control voltage, output
1-27
4-3
0/5 V DC
HVTPCB abnormality detection, input
2-1
4-3
24 V DC
24 V DC supply for BYPSOL, output
2-2
4-3
0/24 V DC
BYPSOL on/off, output
2-3
4-3
24 V DC
24 V DC supply for PFSOL, output
2-4
4-3
0/24 V DC
PFSOL on/off, output
2-5
4-4
5 V DC
CASDSW scan sink, output
2-6
4-4
0/5 V DC (pulse)
CASDSW on/off, input
2-7
2-9
1.2 V DC
DC supply for ESW, output
2-8
2-9
0/5 V DC
ESW on/off, input
3-1
3-2
0/5 V DC (pulse)
Serial communication with ADF (option),
output
3-3
3-4
0/5 V DC (pulse)
Serial communication with ADF (option),
input
4-1
4-3
24 V DC
24 V DC supply, input
4-2
4-4
5 V DC
5 V DC supply, input
4-5
4-3
0/24 V DC (pulse)
HL light intensity control PWM, output
4-6
4-3
0/24 V DC
H on/off, output
4-7
4-4
24/0 V DC
SSW2 on/off, input
5-2
5-1
5/0 V DC
LHPSW on/off, input
Содержание DC-1560
Страница 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Страница 3: ...SERVICE MANUAL DC 1560 2050...
Страница 12: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 23: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...
Страница 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Страница 28: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Страница 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Страница 114: ...3 1 15 1AF Make test copies 1 Place paper in the paper drawer and make test copies Completion of machine installation...
Страница 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Страница 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...
Страница 229: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...