1AF
3-3-1
3-3-1 Precautions for assembly and disassembly
(1) Precautions
• Be sure to turn the main switch off and disconnect the power plug before starting
disassembly.
• When handling PCBs, do not touch connectors with bare hands or damage the board.
• Do not touch any PCB containing IC’s with bare hands or any object prone to static charge.
• Use only the specified parts to replace the fixing unit or optical section thermostats. Never
substitute wire for thermostats, as the copier may be seriously damaged. When installing
a thermostat, ensure the correct clearance, if specified, using a thickness gauge.
• Do not turn the red screw on the image formation unit.
• Use the following testers when measuring voltages:
Hioki 3200
Sanwa MD-180C
Sanwa YX-360TR
Beckman TECH300
Beckman DM45
Beckman 330 (capable of measuring RMS values)
Beckman 3030 (capable of measuring RMS values)
Beckman DM850 (capable of measuring RMS values)
Fluke 8060A (capable of measuring RMS values)
Arlec DMM1050
Arlec YF1030C
• Prepare the following as test originals:
1. NTC (new test chart)
2. NPTC (newspaper test chart)
Содержание DC-1560
Страница 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Страница 3: ...SERVICE MANUAL DC 1560 2050...
Страница 12: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 23: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...
Страница 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Страница 28: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Страница 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Страница 114: ...3 1 15 1AF Make test copies 1 Place paper in the paper drawer and make test copies Completion of machine installation...
Страница 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Страница 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...
Страница 229: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...