1AF
3-6-33
(12)
The halogen
lamp does not
light.
(13)
The halogen
lamp does not
turn off.
(14)
The cleaning
lamp does not
light.
(15)
The fixing
heater does
not turn on
(C61, C63).
Broken halogen
lamp filament.
Optical section
thermostat trig-
gered.
Poor contact in the
composite PCB
connector termi-
nals.
Defective main
PCB.
Defective compos-
ite PCB.
Defective main
PCB.
Defective compos-
ite PCB.
Broken cleaning
lamp coil.
Poor contact in the
cleaning lamp con-
nector terminals.
Defective main
PCB.
Broken fixing
heater wire.
Fixing unit thermo-
stat 1 or 2 trig-
gered.
Broken fixing unit
thermistor wire.
Check for continuity. If none, replace the
halogen lamp (see page 3-3-20).
See page 3-6-5.
If HL CONT (PWM) signal is always output
from CN4-5 on the main PCB, replace the
main PCB.
If the halogen lamp does not turn off when
no HL CONT (PWM) signal is input to CN2-7
on the composite PCB, replace the compos-
ite PCB.
Check for continuity. If none, replace the
cleaning lamp.
Check for continuity across the connector
terminals. If none, replace them.
Run simulation 10 and check if CN13-2 on
the main PCB goes low. If not, replace the
main PCB.
Check for continuity. If none, replace the
fixing heater (see page 3-3-57).
Check for continuity across each thermostat.
If none, remove the cause of blowing and
replace the thermostat.
Measure the resistance. If it is
∞ Ω
, replace
the fixing unit thermistor.
Problem
Causes
Check procedures/corrective measures
Содержание DC-1560
Страница 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Страница 3: ...SERVICE MANUAL DC 1560 2050...
Страница 12: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 23: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...
Страница 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Страница 28: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Страница 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Страница 114: ...3 1 15 1AF Make test copies 1 Place paper in the paper drawer and make test copies Completion of machine installation...
Страница 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Страница 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...
Страница 229: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...