1AF
3-5-5
Code
Contents
Remarks
Causes
Check procedures/
corrective measures
C61
C63
C64
Broken fixing heater fila-
ment
The fixing stabilization
temperature is not reached
within 120 s after the main
switch has been turned on.
The fixing temperature
drops below 80°C/176°F
after having reached the
stabilization level.
Broken fixing unit ther-
mistor wire
The fixing unit thermistor
output voltage does not
change within 7 s after the
main switch has been
turned on with the fixing
temperature remaining
below 100°C/212°F.
Shorted fixing unit ther-
mistor/abnormally high
temperature
The fixing unit thermistor
output exceeds 4.73 V.
Broken fixing
heater fila-
ment.
Fixing heater
installed in-
correctly.
Fixing unit
thermostat
triggered.
Fixing unit
thermistor
installed in-
correctly.
Defective
main PCB.
Broken fixing
unit thermis-
tor.
Poor contact
in the fixing
unit thermis-
tor connector
terminals.
Defective
main PCB.
Shorted fixing
unit thermis-
tor.
Defective
main PCB.
Check for continuity. If none,
replace the fixing heater.
Check the fixing heater and
reinstall if necessary.
Check for continuity. If none,
replace the fixing unit ther-
mostat.
Check the fixing unit thermo-
stat and reinstall if neces-
sary.
Replace the main PCB and
check the operation.
Measure the resistance. If it
is
∞ Ω
, replace the fixing unit
thermistor.
Check for continuity across
the connector terminals. If
none, replace them.
Replace the main PCB and
check the operation.
Measure the resistance. If it
is 0
Ω
, replace the fixing unit
thermistor.
Replace the main PCB and
check the operation.
Содержание DC-1560
Страница 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Страница 3: ...SERVICE MANUAL DC 1560 2050...
Страница 12: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 23: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...
Страница 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Страница 28: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Страница 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Страница 114: ...3 1 15 1AF Make test copies 1 Place paper in the paper drawer and make test copies Completion of machine installation...
Страница 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Страница 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...
Страница 229: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...