1AF
1-3-18
Exposure control for manual exposure and photo modes
The halogen lamp light intensity for manual exposure and photo modes is calculated from
the data obtained by running simulation 24.
Light intensity value
1-2
0
1-3 1-4 1-5 1-6 1-7 1
2
3
4
5
6
7 7-1 7-2 7-3 7-4 7-5 7-6
Manual exposure mode
Photo mode
Exposure scale (Exp.)
Drum potential
680 V DC
Drum potential 850 V DC
Drum potential
680 V DC
Figure 1-3-14
Exposure gradient setting
• Exposure control for manual exposure mode
The gradient between Exp. 1-2 and Exp. 7 is determined from the halogen lamp light
intensity values for Exp. 1, Exp. 4 and Exp. 7 set in simulation 24. For exposure settings Exp.
7-1 and above the drum potential is set 170 V below the normal level and the light intensity
is reduced since the intensity at such high exposure levels cannot be increased by simply
increasing the halogen lamp control voltage. The amount of exposure for the high settings
between Exp. 7-1 and Exp. 7-6 is determined by the halogen lamp light intensity value for
Exp. 7-1 set in simulation 24 and the gradient between Exp. 4 and Exp. 7.
• Exposure control for photo mode
The drum potential is set 170 V below the normal level and the halogen lamp light intensity
value is set low for photo mode.
The halogen lamp light intensity value for photo-mode Exp. 4 is determined by running
simulation 24. The light intensity for manual-mode Exp. 1-4 is used as the value for photo-
mode Exp. 1, which determines the gradient between Exp. 1 and Exp. 4 for photo mode.
Similarly, the light intensity for manual-mode Exp. 7-3 is used as the value for photo-mode
Exp. 7, which determines the gradient between photo-mode Exp. 4 and Exp. 7.
Содержание DC-1560
Страница 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Страница 3: ...SERVICE MANUAL DC 1560 2050...
Страница 12: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 23: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...
Страница 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Страница 28: ...1 1 5 1AF CONTENTS 1 1 Specifications 1 1 1 Specifications DC 2050 1 1 1 1 1 2 Specifications DC 1560 1 1 3...
Страница 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Страница 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Страница 114: ...3 1 15 1AF Make test copies 1 Place paper in the paper drawer and make test copies Completion of machine installation...
Страница 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Страница 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...
Страница 229: ...1 1 27 1AF CONTENTS 3 5 Self Diagnostics 3 5 1 Self diagnostic function 3 5 1 1 Self diagnostic display 3 5 1...