11.6.51 Error 57: POWERLINK error
11.6.51.1 Error 57-1 (emergency code FF00h)
Cause: Powerlink communication disconnected or disrupted!
Suggested steps:
This is possibly an EMC
issue. This is very likely if the
problem occurs when
switching on motor control
and/ or when connecting DC
link power supply.
l
Please check the device cabling for proper
connection.
l
Please check device grounding, i. e. the
connection to a metal backplane and cabinet
connection to earth.
l
Check motor grounding and motor cable
length.
The device was probably
disconnected from the
master controller, or the
master is overloaded.
l
Please check the bus system connection. Try
to replace the cables.
l
Please try to reduce computational load on the
master.
l
Try to increase the master cycle time.
11.6.51.2 Error 57-2 (emergency code FF00h)
Cause: Powerlink fieldbus module defective or not available!
Suggested steps:
This is possibly a hardware
issue
If other measures fail to solve the problem, please
replace the servo controller.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
452
11 Alarms & warnings
11.6.51.3 Error 57-3 (emergency code FF00h)
Cause: Powerlink: failure in powerlink application interface!
Suggested steps:
This is possibly a hardware
issue
If other measures fail to solve the problem, please
replace the servo controller.
11.6.52 Error 58: HYDRAULIK, common error
11.6.52.1 Error 58-1 (emergency code 6100h)
Cause: Hydraulics, p2t: overload of hydraulic pump
Suggested steps:
Please reduce the load.
Hydraulics, cyclic
processing
l
Error during the cyclic execution of the
hydraulics.
l
In any case look at init outputs in the message
window of the DriveManager.