11.6.23.8 Error 22-8 (emergency code 7305h)
Cause: Channel 1 Initialization, EndDat 2.1: CRC error, position data from encoder
Suggested steps:
The transmission is probably disturbed. Please check the wiring to the encoder.
Initialization encoder
channel 1
l
Error during the initialization routines of
encoder channel 1.
l
In any case look at init outputs in the message
window of the DriveManager.
l
The most common cause of error is the wiring
to the encoder.
11.6.23.9 Error 22-9 (emergency code 7305h)
Cause: Channel 1 Initialization, EndDat 2.1: CRC error, parameter data from
encoder
Suggested steps:
The transmission is probably disturbed. Please check the wiring to the encoder.
Initialization encoder
channel 1
l
Error during the initialization routines of
encoder channel 1.
l
In any case look at init outputs in the message
window of the DriveManager.
l
The most common cause of error is the wiring
to the encoder.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
395
11 Alarms & warnings
11.6.23.10 Error 22-10 (emergency code 7305h)
Cause: Channel 1 Initialization, EndDat 2.1: not allowed write operation to write
protected cells or protection cells of the encoder
Suggested steps:
No further information available. Please contact your service provider.
Initialization encoder
channel
l
This is probably a software problem!
l
In any case look at init outputs in the message
window of the DriveManager.
11.6.23.11 Error 22-15 (emergency code 7305h)
Cause: Channel 1 Initialization, SSI: 'MultiTurn' from parameter (543) ENC_CH1_
MultiT
Suggested steps:
Change the input of the multiturn bits of the parameter.
Initialization encoder
channel
l
This is probably a problem of the
parameterization!
l
In any case look at init outputs in the message
window of the DriveManager.